Frequenz.pm6.5 - USA
Page 1.14
Frequency converter
BOGE – VACON frequency converter for screw compressors
1.2
Control keypad
Fault
Fault
code
32
Fan cooling
34
CAN bus error
36
Control unit
37
Device changed
38
Device added
39
Drive removed
40
Unknown device
41
IGBT
temperature
42
Braking resistor
overtemperature
43
Encoder fault
50
Analog input
I
in
< 4 mA
(selected signal
range 4 to 20 mA)
51
External fault
52
Communication
fault
53
Fieldbus fault
54
Slot fault
Possible cause
Frequency converter fan does not
start.
NXS control unit can not control NXP
power unit and vice versa
Supplementary board exchanged.
Different power ratings.
Supplementary board added.
Drive with other power ratings added.
Supplementary board removed.
Drive removed.
Unknown supplementary board or
unknown drive.
Overtemperature protection of IGBT
inverter has detected an increased
short-time overload current.
Overtemperature protection of internal
braking resistor has detected
too heavy braking.
Note deviating fault time data record.
Additional codes:
1 = Encoder 1
A channel not available
2 = Encoder 1
B channel not available
3 = Neither A nor B channel available
4 = Encoder reversed
Current at the analog input is smaller
than 4 mA.
– control cable broken or loose
– signal source faulty
Digital input fault
Connection between keypad and
frequency converter interrupted.
Data connection between Master
appliance and supplementary board is
interrupted.
Supplementary board or slot
defective.
Corrective actions
Contact your nearest BOGE dealer.
Replace control unit
Reset.
Reset.
Reset.
Check loading.
Check motor size.
Extend delay time.
Use external braking resistor.
Check current loop circuit.
Check keypad connection and
possible keypad cable.
Check installation.
If installation is o.k. contact your
nearest BOGE dealer.
Check board and slot.
Contact your nearest BOGE dealer.
Table 1.2: Fault codes