background image

Magnetics that count

BOGEN Magnetics GmbH

 · Potsdamer Straße 12 - 13 · 14163 Berlin · Germany 

Fon +49 (0) 30 81 00 02 - 0 · Fax +49 (0) 30 81 00 02 - 60 · magnetics@bogen-magnetics.com · www.bogen-magnetics.com

AKS17 ins

tallation and oper

ation ins

truction manual (2021/06/16)

11/14

Tips on the Software and Calibration

• For radial and axial orientation it is recommended to use constant velocity as much as possible and the 

calibration duration should cover at least 4 pole pairs. 

• For linear calibration the sensor should at least cover four pole pairs. The user can use the “Calibration 

Duration” to cover the desired measuring area.

• Linear calibration delay is a user preference. It can be chosen as desired to provide time before the 

calibration starts. This delay can be helpful to make sure that the sensor starts moving at the end of the 

delay.

• The “Iteration” parameter is for analog and nonius calibration where more than one calibration is 

recommended and the default is three iterations.

• A backup of the sensor parameters can be saved on the PC by clicking “File” and after that “Save Config”. 

Later the user can use this backup for reprogramming the sensor with the same parameters. Therefor the 

user has to click on “File” and then on “Load Config”.  

Note: The sensor should be connected to the PC before saving or loading configurations.

• The connected sensor serial number, the product order code and parameter descriptions can be found 

under “Help”, then “Product Information”. Note: The sensor should be connected before retrieving the 

product information.

• If you are facing a problem then please make sure that Logging is allowed by verifying the check box. 

Follow the path “File”, “Preference” and activate “Allow Logging”. Then click on “Help” and “Send Report” 

where you can enter a short description of  your problem. We will process your inquiry as soon as we get it.  

Note: This report will be sent by using your local Outlook account. If this is not possible then an instruction 

will be shown.

Commissioning

After mounting the distance measuring system or after replacing the sensing head, verify general system 

operation as follows:
• recalibrate the sensing head,
• switch on the supply voltage of the sensing head,
• move the sensing head along the entire measurement path or revolution,
• check that all signals are present at the output,
• check if the count direction matches the traversing/revolution direction. If this is not the case please mark 

the checkbox in the main window of the software.

Maintenance

The functionality of the measuring system and all related components must be reviewed and recorded 

regularly. For more information and data sheets please visit our website: www.bogen-magnetics.com

Summary of Contents for AKS16

Page 1: ...ntent Safety Instructions 2 Electromagnetic Compatibility 3 Intended Use 3 Function and Properties 3 Assembly and Installation 4 Programming Device 4 Configuring the AKS17 Sensing Head 6 Protocol Data...

Page 2: ...ems such as airplanes etc Risk of pinching There is a risk of getting pinched between the sensing head and the magnetic tape This can lead to injury or mechanical damage Avoid getting with your limbs...

Page 3: ...f magnetic scales and sensing heads capable of non contact position detection for linear and rotary applications Fields of deployment capital equipment automation medical engineering electrical engine...

Page 4: ...all or vice versa is a count for the period counter up down counter If signal A is preceding signal B the counter increases If signal B is preceding signal A the counter decreases The Z pulse appears...

Page 5: ...re the parameters of an AKS17 sensing head can be changed for a successful calibration The software sets the sensing head parameters for the correct master nonius periods 128 127 120 256 255 240 512 5...

Page 6: ...tory on your Windows PC To install the driver execute the specific program USB_Adapter_00052040_Driver exe Connecting the device for the calibration setup Mount the sensing head correctly per mechanic...

Page 7: ...OGEN calibration software AKS16 and AKS17 CalibrationGUI Choose AKS17 from the Sensor combo box Choose the desired sensor parameters see technical data sheet for full listing of sensor parameters Plea...

Page 8: ...scale or both if needed In case of linear calibration the user will be prompt with the countdown window on every iteration The user has to move the magnetic target during the calibration process In l...

Page 9: ...circle is red and in the textbox to the right the user can see the corresponding error message 3 Nonius calibration Max and Min represent the maximum and minimum percentage value from result regardin...

Page 10: ...ion to be 1050 Ticks Now the user can enter 239194 Current Position Resolution mod Resolution in the Desired Offset and then click Set The software automatically calculates the smallest possible offse...

Page 11: ...The sensor should be connected to the PC before saving or loading configurations The connected sensor serial number the product order code and parameter descriptions can be found under Help then Prod...

Page 12: ...er can freely disconnect the cables and reconnect a new sensor if desired Q How can I choose calibration duration A Calibration duration represents a time variable The duration should cover at least f...

Page 13: ...e it is recommended to repeat the calibration with higher velocity or higher duration and cover all the scale Calibration failed invalid calibration data cycle count Very noisy environment Please make...

Page 14: ...manual Rev 1 4 2021 06 16 14 14 EU Declaration of Conformity Acc to EU regulation for Electromagnetic Compatibility 2004 108 EU European Standard for Electromagnetic Compatibility EN 61326 1 2006 EMC...

Reviews: