Remote Interface (TAM-B)

The TMC-4 can be accessed remotely by an external contact
closure between a station external input and ground. The TAM-
B provides this closure after being accessed as an extension of
the telephone system. When the external inputs are activated:

1

.The unit connects the respective station, the station's in-use

LED illuminates. A ready beep is sent every 2 seconds to the
calling station. The station is reserved until released by the
TAM-B, the user, or the TMC-4.

2. The TMC-4 waits for DTMF tones or a disconnect code. If
key pad numbers [0] through [9], [#] [0] through [#] [9], or [*]
[*], or [*] [

1

] through [*] [9] are pressed, the controller will try

to send the corresponding command. If successful, a valid tone
will be heard, if unsuccessful, an error tone will be heard.

3.After a preset time, if the user does not hang up or send the
disconnect code ([*] [0]), the TAM-B will automatically hang up.

Releasing a station directly from the TMC-4

If at any time it becomes necessary to free the device cur-
rently being controlled, it can be released directly from the
TMC-4

To release a station:

1

. Press [*]. The in-use LEDs of all stations currently in use will

flash.

2. Enter the number of station to be released. That station will
be released and the stations light will go out.

Service

There are not user-serviceable parts within the unit. The war-
ranty may become void if repairs are by other than Bogen
Factory Service Department. For information on warranty
repair, contact the Factory.

Technical service is available for the Bogen Applications
Engineering Department.

Bogen Communications, Inc.
50 Spring Street, Ramsey, NJ 07446
U.S.A.
Phone (20

1

) 934-8500

Fax (20

1

) 934-9832

Specifications

Interface

LEDs

4 Yellow STATIONS IN USE

1

Red ERROR

1

Green LEARN

1

Green POWER

Telephone style keypad
STATION INPUTS terminal block
EXTERNAL INPUTS terminal block
INFRARED SIGNAL OUTPUTS RCA jack

Digital Section

CPU - Intel 80C32 

1

2MHz

Memory - 

1

each 27C256 EPROM

3 each 28C64 EEPROM's

Infrared Section

Detectable IR transmission schemes:
1. Envelope Modulation
2. Pulse Modulation

Carrier Modulation Range: 25-92 kHz
Pulse Modulation Width:

1

5x

1

0-6 sec.

Power Requirements

1

20 VAC, 60  Hz, 0.

1

A

5

Summary of Contents for TMC-4

Page 1: ...ELEMEDIA CONTROLLER Model TMC 4 Installation and Operation Instructions RELEASE MANUAL PROGRAM 1 2 3 4 STATIONS IN USE PROGRAM WINDW LEARN ERROR POWER 1 2 3 4 5 6 7 8 9 0 MODEL TMC 4 TELEMEDIA CONTROLLER ...

Page 2: ... one Bogen Model TAM B Telephone Access Module is required for each media station Diodes CR27 and CR28 must be removed from the TAM B for proper DTMF communications Refer to Figure 1B below Follow the instructions included with the TAM B for proper connection to the telephone system Connect output terminals PT and PR on theTAM B to the A and G terminals of a station on theTMC 4 Connect the contact...

Page 3: ...he TMC 4 controller 1 Press and hold down the MANUAL PROGRAM key for at least 5 seconds All STATIONS IN USE LEDs will begin flash ing After 5 seconds all LED s will light solid station select mode 2 Enter a station number 1 2 3 or 4 All other station LEDs will go out A Aim the media source s remote control at the TMC 4 PROGRAM WINDOW the remote control should point directly at the center of the PR...

Page 4: ...quence 0 is received or if the MultiCom 2000 sends a disconnect code the TMC 4 will disconnect the station and shut off the station s in use light 2 Enter a station number 1 2 3 or 4 All other station LEDs will go out 3 To teach the TMC 4 a command enter a command number on the TMC 4 keypad 0 0 to 2 9 see Table 1 At this point the LEARN LED will begin flashing 4 Aim the remote control at the PROGR...

Page 5: ...ce cur rently being controlled it can be released directly from the TMC 4 To release a station 1 Press The in use LEDs of all stations currently in use will flash 2 Enter the number of station to be released That station will be released and the stations light will go out Service There are not user serviceable parts within the unit The war ranty may become void if repairs are by other than Bogen F...

Page 6: ...Copyright 2002 Bogen Communications Inc Part No 54 5929 02r1 Printed in U S A 0802 ...

Reviews: