background image

 

7

4)

 

Inspection of proper fastening of the RIP, tightening of contacts, and wire integrity; 

5)

 

Replacing the batteries when necessary but at least once per 5 years. 

4

 

MANUFACTURER WARRANTY 

4.1

 

The manufacturer guarantees that the RIP meets technical requirements specified in 

the manuals if the user follows the instructions for shipment, storage, installation, and usage. 

4.2

 

Warranty period is 18 months but no more than 24 months from the manufacturer's 

date of issue. 

4.3

 

In  case  of  any  issue  related  to  setting  and  use  of  the  product,  please  contact  the 

technical support: +7 (495) 775-71-55 or e-mail: 

support@bolid.ru

4.4

 

When  submitting  the  product  for  repair,  it  shall  be  accompanied  with  descriptions 

of possible fault. 

Claims shall be submitted to the following address: 
NVP BOLID CJSC, Pionerskaya #4, Korolyov city, Moscow region, Russia, 141070. 
Phone/fax: (495) 775-71-55 (multiline), 516-93-72. 

E-mail: 

info@bolid.ru

; Support :

 

support@bolid.ru

 

http://bolid.ru

.

 

5

 

CERTIFICATES 

5.1

 

Battery  Backed  Power  Supply  RIP-24  model  01  (RIP-24-3/7M4)  meets  the 

requirements  of  technical  regulations  of  the  Custom  Union  TR CU 004/2011; 
TR CU 020/2011. Approved by Conformity Certificate 

 RU 

С

-RU.

МЕ

61.

В

01270. 

5.2

 

Manufacture  of  RIP-24  model  01  (RIP-24-3/7M4)  is  approved  by  Conformity 

Certificate GOST R ISO 9001-2015 

 

РОСС

 RU.

АБ

66.

К

00003. 

Summary of Contents for RIP-24

Page 1: ... GOST 15150 69 but to be used within temperature ranges of 263 К to 313 К 10 С to 40 С and ambient humidity of up to 90 at 298 К 25 С 1 1 6 In terms of mechanical tolerance the RIP corresponds to Category LX in accordance with GOST 12997 84 vibration within 1Hz to 35 Hz when accelerated up to 4 9 m s2 0 5 g 1 2 Specifications 1 2 1 The main power supply is the mains power 150 253 V 50Hz 1 2 2 The ...

Page 2: ...ra 12 V batteries of 17 Ah each placed in a special Box 24 Mod 0 to increase the time of operation from the batteries with total capacity of all RIP batteries being equal to 2 24 Ah 1 2 16 The RIP provides immunity to electromagnetic interference of the third severity level according to Russian Standard GOST R 50009 2000 1 2 17 Radio disturbances from the RIP operation do not exceed the values spe...

Page 3: ... third or higher safety qualification level can mount and maintain the RIP CAUTION Connecting the RIP to the mains utility power please KEEP UP the correct coupling of LINE and NEUTRAL TERMINALS in agreement with the picture located inside the cabinet closely to power terminal block 2 2 Mounting and Preparing for Operation 2 2 1 The RIP is to be installed on walls or other structures in the protec...

Page 4: ...rder to indicate remotely switching the RIP to backup power or a short circuit failure connect the RIP to the alarm loop of the devices to be powered An example of connecting the RIP with alarm loops of such devices as Signal 20P S2000 4 and similar is shown in Figure 2 A termination resistor 4 7 K provided with the devices is to be installed inside the RIP XP2 XP3 RED Output 27V 3A Line Neutral X...

Page 5: ...mains power supply fails the batteries begin to power the load circuit the 24 V indicator being turned on and the sounder going off periodically The POWER and CHARGE indicators are off e If the voltage of the batteries has dropped to 22 V the sounder switches on and off five to ten times more rapidly It is necessary to take measures to restore mains power line as soon as possible f If the voltage ...

Page 6: ...arge discharge cycle Note After disconnecting the batteries from the load circuit and recovering utility power it is recommended to check the battery charge discharge cycle If the CHARGE LED has been still lit after 24 hours since having restored power then the battery operability has been to be checked If extra batteries are connected the charge time will be increased 2 3 3 How to Turn the RIP Of...

Page 7: ...e technical support 7 495 775 71 55 or e mail support bolid ru 4 4 When submitting the product for repair it shall be accompanied with descriptions of possible fault Claims shall be submitted to the following address NVP BOLID CJSC Pionerskaya 4 Korolyov city Moscow region Russia 141070 Phone fax 495 775 71 55 multiline 516 93 72 E mail info bolid ru Support support bolid ru http bolid ru 5 CERTIF...

Page 8: ...ts of state standards and applicable technical documentation and approved as ready for operation 6 2 Battery Backed Power Supply RIP 24 model 01 RIP 24 3 7M4 is packaged by CJSC NVP Bolid in line with the requirements provided in the current technical documentation Responsible for acceptance and packaging QCD _____________________________ ________________________ Full Name Data Month Year ...

Reviews: