SG2060 series 3 Item Settings
Page 11
and to use lower sensitivity for
outdoor or environment with lots of
interference like hot wind, smoke,
near window etc. Furthermore, the
sensitivity of the PIR is strongly
related to the temperature. Higher
temperature leads to lower
sensitivity.
Please note that if Time Lapse is set
to Off, then PIR Trigger can’t be set
to Off
.
PIR Interval
This parameter indicates how long
the PIR (Passive Infrared motion
sensor) will be disabled after each
triggering in ON mode. During this
time the PIR of the device will not
react to the motion of human (or
animals). The minimum interval is 0
second, it means the PIR works all
the time. The maximum interval is 1
hour. It means the PIR will be
disabled for 1 hour after each
triggering. Press LEFT or RIGHT to
decrease or increase the value.
Work Hour
This parameter defines a certain
time in a day when the camera can
be triggered, while in the rest of the
time the device is shut off. The
effective value ranges from 00:00 to
23:59.
The default set is Off which means