Operation
Starting
1. put left feet on stop switch panel( left the foot will stop the engine)
Turn the key and starting the engine
2. After idle speed running 30 seconds to warm up the engine.
3. Trample the throttle with right feet to increase the engine speed several
times, the check the hydraulic oil pressure.
Caution: Hydraulic oil pressure setup 2.6MPA
Adjust the bolt show on photo can setup the oil pressure.
4. Check Gear oil pump shell temperature, if shell temperature high means
hydraulic oil didn’t come into the gear pump