Multi-Appliance Slimline Control
Bonaire Control Systems
Page 12
Ducted Gas Central Heating
OPERATING THE SLIMLINE CONTROLLER
To operate your Slimline Controller simply press the ON / OFF button. The unit will then display the default
or last used settings and will be ready to operate. Any changes made to the Slimline Control settings will
have a 3 second delay before the unit responds.
If an Evaporative cooler is connected in conjunction with a central heater, you may have to toggle through
the modes to select the heating functions.
H
EAT
M
ODE
STEP 1
Turn the Slimline Controller ON by pressing the
ON/OFF
button.
NOTE
:
Your Slimline Controller is designed to
automatically detect the appliances you have
installed. Controller options not required for your
connected appliances will be hidden and not
displayed, therefore some menu items shown in this
instruction may not appear.
STEP 2
Press the
MODE
button until Heat LED turns ON.
STEP 3
Press the
UP/ DOWN
buttons to increase or decrease
the set temperature.
NOTE:
The controller measures the room
temperature using a thermostat inside its housing.
When the ROOM TEMP is cooler than the SET TEMP
the heater will come on after approximately a 30
second ignition process. The controller will run the
heater until it measures temperature a little above
your SET TEMP. The unit will turn off until the
temperature falls a little below SET TEMP before
restarting.
STEP 4
Press the
ON/OFF
button to turn the heater OFF.
OPERATION:
The Slimline Controller remembers your SET TEMP setting and uses it the next time you turn
it ON. The operation of the 4 and 5 star heaters is as follows:
•
If at start up the room temperature is below the set temperature, the central heater will
start up at high fan speed and high gas rate quickly bringing your house up to
temperature.
•
As the room temperature gets closer to the SET TEMP the central heater will reduce
the room air fan and the gas rate to the burner.
•
When the thermostat reaches the SET TEMP the central heater will shut down. When
the temperature has dropped below SET TEMP the unit will restart.
•
For economical operation, set a low SET TEMP during the day when you are active.
Switch the controller OFF when asleep and ON again when awake.