Multi-Appliance Slimline Control
Bonaire Control Systems
Page 17
Ducted Evaporative Air Conditioning
INTRODUCTION
Your ducted evaporative air conditioner is engineered to meet the rigors of our harsh Australian
environment. Operated and maintained in accordance with this manual, it will provide you with years of
cool and environmentally friendly operation. Please take the time to read this manual.
The principal of your unit is to introduce fresh air, which is washed through the filter pads to provided cool
fresh air. The air is relieved taking with it any heat loading on the home.
E
XHAUST
It is essential for successful operation of evaporative air-conditioning that there to be sufficient relief
openings in the area to be ventilated. Open doors and windows will usually provide this.
The minimum relief opening should be as per the table guide set out below. It is recommended that
ceiling vents or exhaust fans be used where there is any doubt about there being sufficient relief area
available. Ceiling exhaust fans or ceiling vents should have a capacity equivalent to that of the air
conditioner.
MODEL
MINIMUM RELIEF
AREA
Small
0.85 m²
Medium
1.19 m² to 1.48 m²
Large
2.02 m²