background image

Note:

•  If “60”, “120”, or “180” is chosen, 

the scale will turn off after the 
designated number of seconds of 
inactivity.

•  If the Auto-off function is disabled, 

the scale will not shut off on its 
own.

Note:

 To maintain a longer battery life, 

please turn off the scale by pressing 
the ON/OFF button after each use.

CALIBRATION

1.  While the scale is off, press ON/

OFF button to turn on the scale.

 

‐ The LCD will read “0.0g”.

2.  Press and hold the MODE button 

until the display shows

3.  “CAL”, then release the button. 
4.  Press MODE button again.

 

‐ “500g” will flash on the display.

5.  Place a 500g calibration weight 

onto the center of the platform.

6.  The LCD will read “PASS” then 

return to the normal weighing 
mode.

7.  Calibration is complete.

WARNING 

MESSAGES

•  “LO”: Low voltage

 

‐ Replace the batteries.

•  “EEEE”: Overload

 

‐ Quickly remove weight from 

platform to protect the scale. 

•  “UNST”:

 

‐ Scale is not steady during start 

up. Please turn off scale, set 
on a stable surface and restart 
scale.

 

‐ Water is inside the scale. 

Shake out excess water and 
let dry.

WASHING 

INSTRUCTIONS

This scale has been treated with a 
liquid repelling Nano- coating which 
allows you to wash your scale without 
damaging the internal electronics. 
Please follow these instructions when 
washing:
1.  Hand wash only with mild soapy 

water.

2.  Wash only the platform. Rinse 

other parts with clean water if 
needed.

3.  After washing the scale, shake out 

excess water. It is best to do this 
by firmly grasping the scale in one 

Summary of Contents for BV2100SC

Page 1: ...y bonavitaworld com Six auto modes for ease of use and hands free operation Unique nano coating helps prevent water damage Programmable auto off settings Built in timer for brewing accuracy 2000 gram...

Page 2: ...uch LIMITED WARRANTY 1 year limited warranty from the date of original purchase 1 This warranty extends only to the original retail purchaser or gift recipient Keep the original sales receipt as proof...

Page 3: ...are not authorized by the manufacturer and or if spare parts are used other than the original ones 6 Failure to comply with any of the important safeguards listed in this manual will void the limited...

Page 4: ...can be set to 60 seconds 120 seconds 180 seconds or disabled manually Operating modes Four 4 Automatic AUTO modes and two 2 Manual HAND modes Power 2 AAA batteries Operation temperature range 50 to 85...

Page 5: ...teries by following these steps Mode setting 1 Turn on the scale by pressing the ON OFF button Wait until the LCD displays zero 2 Press the MODE button The display will read AUTO1 AUTO2 AUTO3 AUTO4 HA...

Page 6: ...isplay for five 5 seconds after removing the cup After a five 5 second delay time returns to 0 00 and weight returns to 0 0g Mode AUTO4 Auto tare and Auto timer with timer starting when liquid hits th...

Page 7: ...se the timer press the TIME button 4 To reset the timer to 0 00 press the TIME button again When timer reaches 9 59 it will reset to 0 00 TARE FUNCTION Tare function is disabled under AUTO mode Under...

Page 8: ...The LCD will read PASS then return to the normal weighing mode 7 Calibration is complete WARNING MESSAGES LO Low voltage Replace the batteries EEEE Overload Quickly remove weight from platform to pro...

Page 9: ...d disappear If the scale displays UNST or the readings jump after washing then water is still inside the scale Simply shake out the excess water and let your scale dry longer Batteries should not come...