20
en
Problem
Possible cause
Solution
The appliance isn’t working.
The plug is not in the power socket.
Plug in the appliance to the power socket.
The warning lamp that indicates that the water
Empty the water reservoir and replace it.
reservoir is full is flashing.
The ambient temperature is above 35 °C or
The fuse has been activated and this ensures
below 5 °C.
that the appliance cannot be started.
The dehumidifying does not work.
The air filter is blocked.
Clean the air filter as directed under
«Maintenance».
The air intake or outlet is blocked.
Remove the blockage in the air intake or
outlet.
No air is being circulated.
The air filter is blocked.
Clean the air filter as directed under
«Maintenance».
The appliance is making a noise.
The appliance is in an unsafe place or is
Place the appliance in a firm, safe place.
unstable.
The air filter is blocked.
Clean the air filter as directed under
«Maintenance».
Don’t forget
Discarded electrical appliances may never
be placed with normal household refuse.
Bring this product to the local refuse coll-
ection place, so that it can be disposed in a
proper manner.
Technical data
Voltage supply
220 - 240 V / 50 Hz
Power consumption
360 W
Dehumidifying power (at 30 °C, 80% RH)
18 lit/day
Water reservoir
2.7 l
Coolant
R134A
Coolant amount
160 g
Dimensions (l x w x h)
310 x 230 x 535 mm
Weight
11.6 kg
Trouble shooting
Do not try to repair or dismantle the appliance yourself. Before calling in a repairman, check the following points:
27175 D7064-EU-Manual_vec.indd 20
7.6.2007 17:37:52 Uhr