-26-
SAFETY
SAFETY WARNINGS FOR THE APPLIANCES USING R290
COOLING FLUID (PROPANE)
Propane is a natural gas that doesn’t affect the environment but is inflammable.
It is therefore essential to ensure that all refrigerant pipes are not damaged before
connecting the appliance to the mains supply. Every 8 gr. Of refrigerant, the installation
room must have a 1 m³ minimum volume. The amount of refrigerant of the appliance
is indicated on the rating plate of the device. In the event of leakage of the refrigerant,
avoid using open flames or sources of ignition in the vicinity of the area of the leak. Be
careful not to not damage the refrigerant circuit pipes during positioning, installation
and cleaning.
Avoid using naked flames or sparks inside the appliance.
IN THE EVENT OF DAMAGE:
•
Keep the appliance far from flames or ignition sources.
•
Ventilate the room well for a few minutes.
•
Switch off the equipment, remove the power supply plug.
•
Inform customer service
•
The higher the refrigerant content in the equipment, the larger the room must be
hosting the equipment.
•
In rooms that are too small, a mix of flammable air and gas can form in the event
of a leak.
WARNING!
Do not damage the refrigerant circuit.
WARNING!
Do not damage the inner or outer walls of the appliance: the refrigerant
fluid circuit may be damaged. In case of damage to the walls, do not start the appliance
and contact a qualified service technician.
WARNING!
This appliance must only be installed by suitably qualified personnel in
order to reduce the risks connected with flammability.
USE
THE APPLIANCE IS INTENDED FOR THE SOLE STORAGE OF PRE-PACKAGED PRODUCTS.
The manufacturer cannot be held liable for damage caused by people, property or the equipment itself due to
display of products other than the afore-specified.
WARNING!
Do not use electrical appliances inside the compartments of the appliance
for storing frozen foods if these are not those recommended by the manufacturer.
WARNING!
Never use mechanical devices or any other means to accelerate the
defrosting process, other than those recommended by the manufacturer.
WARNING!
Keep the ventilation openings in the appliance casing or in the recessed
structure clear of obstructions.
WARNING!
Do not store explosive substences such as aerosol cans with flammable
propellant in this aplliance.
ATTENTION!
Maintenance must be carried out by technical staff trained and enabled for
intervention on the flammable refrigerants.