-34-
MAINTENANCE
WARNING!
Any work carried out on the appliance by the user strictly requires the power plug being
disconnected from the mains socket.
ATTENTION!
Use protective shoes and gloves during maintenance operations.
The equipment manager is obliged to check and comply with the maintenance deadlines in the table
indicated below.
PUTTING INTO OPERATION
If the cabinet has been sharply tilted while being sited or for mounting of accessories, it must be left to stand for
at least three hours before being started to allow the lubricating oil to settle in the compressor.
Failure to do so can cause total destruction of the compressor refrigerating system.
Check that the voltage on the identification plate is the same as that of the network.
THE ELECTRICAL SUPPLY LINE TO WHICH THE REFRIGERATOR WILL HAVE TO BE CONNECTED
IS TO BE PROTECTED BY A VERY SENSITIVE DIFFERENTIAL SWITCH (Rc=16A,Dc=30mA); IT IS
ALSO TO BE LINKED TO THE GENERAL EARTHING PLANT.
Earthing is necessary and compulsory by law.
Absolutely never use reduction units, patch cords, adapters or multiple socket outlets to connect
the counter. DIRECTLY connect the equipment to the mains.
The cable should be fully extended and located where it is unilikely to be struck, caught or stepped
on, away from water and the other liquids and heat sources and must not be damaged.
In case of breakage of the power cable of the cabinet, it must be replaced by the manufacturer or
by instruction it change of it.
Follow the manufacturer’s instructions to install the unit, using qualified personnel and complying
with the electrical regulations for the specific country.
Incorrect installation may cause injury and damage; the manufacturer is not liable for this.
The manufacturer disclaims all responsability for any damage to people or things due to incorrect
observance of this rule.
OPERATION
FREQUENCY
ORDINARY /
EXTRAORDINARY
MAINTENANCE
AUTHORISED
STAFF
Cleaning the outer surface
Based on use
Ordinary
User
Cleaning the accessible inner parts
(do not use tools)
Based on use
Ordinary
User
Checking the power supply, electrical plugs and/or sockets
Six-monthly
Ordinary
User
Seals intactness check
Six-monthly
Ordinary
User
Check the acceptable condition of warning plates
Six-monthly
Ordinary
User
Water collection tank cleaning
Based on use
Ordinary
Technical support
Fridge system tubing intactness check
Six-monthly
Ordinary
Technical support
Inspecting the cables and inner power connections
Six-monthly
Ordinary
Technical support
Replacing the led lights
-
Extraordinary
Technical support
Replacing the power supply cable
-
Extraordinary
Technical support
Control panel replacement
(electronic control unit)
-
Extraordinary
Technical support
Any other maintenance operation not planned in the previous points should be carried out
by the support centres authorised by our dealers or by qualified staff.