User Manual n°648261 –
Page 8
1.5.3 START AND STOP OF A CYCLE WITH TIMER
1
Open the door and introduce the products to be cooled.
Check the core probe is well installed on its support.
Close the door.
2
Selection :
Press
)
The Cycle and Chilling leds light up
The factory pre set cycle duration is
displayed.
3
Mode :
Press
)
or
The Chilling or freezing leds light up, the
factory pre set cycle duration is or
displayed.
4
Settings (eventual) :
Press
)
or
To modify the cycle duration. Display of the cycle duration
in real time or
5
Start :
Press
)
The ‘Running cycle’ led lights up, the remaining cycle
duration is displayed in real or
time.
The cycle starts with a weak ventilation power, until the
+12°C level set in factory is reached, and automatically
moves to strong ventilation mode until the end of the cycle
(except for MI3).
6
Fragile products :
Press
)
(for a few seconds during the
cycle)
Avoid frost deposit on the products by limiting the air
temperature to –15°C (blast chilling cycle).
This function can be set by modifying the factory settings,
with a different air temperature (cc parameter) and/or
(except for MI3) a weak ventilation (F1 parameter)
Attention : This function must only be used with small loads
7
Automatic end of cycle
The ‘Preservation after cycle’ led lights up.
The bell
rings for a few seconds.
The appliance moves to the preservation stage at the
temperature of +3°C or of –20°C (except for MI3) with a
weak ventilation power.
Opening of the door
during the cycle
Temporary stop of the running cycle.
When the door is closed, the cycle starts again.
During the cycle,
Press(a few sec.)
)
Full and definitive stop of the running cycle.
N
O
T
A
All operating parameters set in factory can be modified when needed(see ‘instructions’).