Instructions n°648261 –
Page 11
TABLE OF PARAMETERS (2
nd
part)
Code
Parameters
Min
Max
Fact.
F
= VENTILATION
F0
Ventilation ON in preservation cycle
0 = weak, 1 = strong
0
1
0
(2)
F1
Ventilation ON with fragile products
0 = weak 1 = strong
0
1
1
F4
Ventilation ON in defrost cycle
0 = weak, 1 = strong
0
1
0
F5
Ventilation rythm after draining
0
15
0
u
= OUTLET ASSIGNATION
u0
RL1 relay operation
0 = on/off, 1 = alarm
0
1
1
u1
RL1 relay polarity
0 = NO, 1 = NC
0
1
0
i
= PRINTER
i0
Printer presence
0 = no, 1 = yes
0
1
0
(2)
i1
Printing frequency in chilling cycle
(mn)
0
60
5
(2)
i2
Printing frequency in preservation cycle
(mn)
0
60
30
(2)
i3
Printing at the beginning of the cycle
0 = no, 1 = yes
0
1
1
(2)
i4
Date setting
Day
1
31
(3)
(2)
i5
Month
1
12
(3)
(2)
i6
Year
990
050
(3)
(2)
i7
Time setting
Hour
0
23
(3)
(2)
i8
Minute
0
59
(3)
L
= NETWORK
L1
Instrument address
1
15
1
L2
Instrument group
0
7
0
L3
Timeout link
2
250
7
L4
Transfer rate
0 = 1200 bauds
1 = 2400 bauds
2 = 4800 bauds
3 = 9600 bauds
0
3
1
L5
Machine code
A
Y
(3)
A
L6
Machine number
1
99
(3)
1
(2)
: Configuration parameters on level 1, accessible to user.
(3)
: Configuration parameters which must be set during the installation.