Page 16
BONNET CIDELCEM GRANDE CUISINE
Siége social:
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex
3. INSTALLATION: CONNECTION
3.1 ELECTRICAL CONNECTION
Earth bonding point
Whatever the model the electrical connection is at the rear.
- Remove the cover
- Feed cable through cable gland and tighten
- Connect up wires
- Connect earth to bonding point provided.
- Replace cover.
IMPORTANT:
Only use power supply cables of H07 RNF type with section as indicated below:
Voltage
Cable
380 / 415
5 x 2.5 mm
2
Provide suitable multipolar isolator (with a contact opening distance of at least 3 mm).
The installation must comply with current electrical regulations (France NFC 15.100).
The appliance must be earthed
.
The various electric appliances must also
be earth bonded
(every metal part on the same voltage) via the terminal provided located next to connection cord-grip.
The manufacturer can not be held responsible in case of failure to heed these
instructions.