3. INSTALLATION: CONNECTION

3.1 ELECTRICAL CONNECTION

Earth bonding point

Whatever the model the electrical connection is at the rear.

- Remove the cover
- Feed cable through cable gland and tighten
- Connect up wires
- Connect earth to bonding point provided.
- Replace cover.

IMPORTANT: 

Only use power supply cables of H07 RNF type with section as indicated below:

Voltage

Cable

380 / 415

5 x 2.5 mm

2

Provide suitable multipolar isolator (with a contact opening distance of at least 3 mm).
The installation must comply with current electrical regulations (France NFC 15.100).

The appliance must be earthed

.

 The various electric appliances must also 

be earth bonded

(every metal part on the same voltage) via the terminal provided located next to connection cord-grip.

The manufacturer can not be held responsible in case of failure to heed these

instructions.

Summary of Contents for P072188

Page 1: ...rsonnel approved by the manufacturer and in accordance with current regulations and standards If any modifications are made the manufacturer can accept no responsibility whatsoever These appliances must be used in a well ventilated area Read the notice carefully before installation The unit must be kept on its base for handling until it is in its final location N 390 272 9 ...

Page 2: ...Cedex CONTENTS INDUC CHEF A TECHNICAL CHARACTERISTICS 2 B TECHNICAL INFORMATION FOR THE INSTALLER 1 Location of the identification plate 6 2 Installation General features 7 2 1 General requirements 7 2 2 Handling 7 2 3 Unpacking 7 2 4 Removing the facia 8 2 5 to 2 9 Installation 8 3 Installation connection 16 ...

Page 3: ...duc chef P072188 MODEL B D7 IN33 DIMENSIONS mm Height 270 Width 400 Depth 730 WEIGHT KG 36 PACKAGING mm Height 570 Width 500 Depth 840 TOP COMPRISES Front hob 220 mm Watts 2800 Rear hob 180 mm Watts 2800 ELECTRICITY Voltage I Max P kw 400 V 3 N a c Three phase 400V N E 13 6 ELECTRICAL CONNECTION 645 mm from floor Non contractual document Edition 02 2000 EN138 ...

Page 4: ...L B B7 IN33 DIMENSIONS mm Height 900 Width 400 Depth 730 WEIGHT KG 45 PACKAGING mm Height 1150 Width 500 Depth 840 TOP COMPRISES Front hob 220 mm Watts 2800 Rear hob 180 mm Watts 2800 BASE COMPRISES Technical cupboard ELECTRICITY Voltage I Max P kw 400 V 3 N a c Three phase 400V N E 13 6 ELECTRICAL CONNECTION 200 mm from floor Non contractual document Edition 02 2000 EN139 ...

Page 5: ...c chef P072693 MODEL B D9 IN63 DIMENSIONS mm Height 270 Width 400 Depth 920 WEIGHT KG 47 PACKAGING mm Height 570 Width 500 Depth 1030 TOP COMPRISES From hob Watts 5600 Rear hob Watts 2800 ELECTRICITY Voltage I Max P kw 400 V 3 N a c Three phase 400V N E 13 9 ELECTRICAL CONNECTION 645 mm from floor Non contractual document Edition 02 2000 EN140 ...

Page 6: ... MODEL B B9 IN63 DIMENSIONS mm Height 900 Width 400 Depth 920 WEIGHT KG 56 5 PACKAGING mm Height 1150 Width 500 Depth 1030 TOP COMPRISES Front hob Watts 5600 Rear hob Watts 2800 BASE COMPRISES Technical cupboard ELECTRICITY Voltage I Max P kw 400 V 3 N a c Three phase 400V N E 13 9 ELECTRICAL CONNECTION 200 mm from floor Non contractual document Edition 02 2000 EN141 ...

Page 7: ...TALLATION MANUAL 1 IDENTIFICATION PLATE The identification plates are fixed on the inside of the cupboard door or on the front see Diagrams below In any correspondence about your equipment please quote The model number Model The serial number Fab Nr The date Date Location of the identification plate Identification plate ...

Page 8: ...t a wall The latter must be of non combustible materials or if not should be covered with an appropriate material good insulator non combustible Attention Table top Induction must on no account be put onto a closed base and the technical cupboard of freestanding Induction should not be used for storage Table top units should only be installed on Fixed frame with undershelf and adjustable legs Mobi...

Page 9: ... the generator disconnect them at the generator For re assembly reverse the above operations A label stuck on one of the facia card covers indicates how to reconnect the cables 2 5 ASSEMBLY ONTO A SINGLE UNDERFRAME Place appliance on the underframe with the rear of the appliance and the underframe approximately aligned The underframe is symmetric front and rear are identical Push the unit backward...

Page 10: ...m bolts 5mm Ø washers for boiling pan or deep fat fryer connected to cooking unit a captive nut is located in the side rails behind the facia Use HM5 x 16mm nuts and bolts 5mm Ø washer to connect cooking units together having removed the M5 captive nut from one of the 2 appliances from the screw side using a screwdriver 2 6 ASSEMBLY ON AN INDIVIDUAL UNDERFRAME Fasten appliances together 11 at the ...

Page 11: ...the legs using pliers a Position pliers against the fold b Hand tighten as far as possible c Finish tightening with HM5 x 60 bolt 2 7 INSTALLATION OF TOPS ON FIXED OR MOBILE FRAME Instructions Toque Blanche Grande Carte Length A 400 800 1200 1600 400 800 1200 1600 Length B 350 750 1150 1550 350 750 1150 1550 Length C 410 600 ...

Page 12: ...G BRACKETS Instructions Toque Blanche Grande Carte Length A 400 800 1200 1600 400 800 1200 1600 Length B 350 750 1150 1550 350 750 1150 1550 Length C 194 594 994 1394 194 594 994 1394 Length D 567 667 Length E 163 253 2 8 1 PROCEDURE FOR INSTALLATION OF TOPS ONTO WALL FRAME Fix brackets A onto wall in positions as indicated previously do not tighten screws ...

Page 13: ...all frame s onto brackets A Using HM6 x 16 screws 6 mm washers Adjust level using the adjustment in the bracket slots then fully tighten Fasten cantilever fixings B Level by adjusting plastic base plate C Position units on the frame s Fix together at the flue and at front fascia levels Fasten to wall bracket with plates D ...

Page 14: ...00mm cupboard with any type of cooking or neutral top possible except induction 2 A Technical compartment at the end of the range 250mm wide with neutral top access panel in the end The technical compartment is recommended if the stop cocks isolators and governors are to be housed in the range Toque Blanche Grande Carte Length A N1 400 N2 800 N3 1200 ETC N1 400 N2 800 N3 1200 ETC Length B 710 900 ...

Page 15: ...e of cooking or neutral top possible except induction 2 A Technical compartment at the end of the range 250mm wide with neutral top access panel in the end The technical compartment is recommended if the stop cocks isolators and governors are to be housed in the range Toque Blanche Grande Carte Length A N1 400 N2 800 N3 1200 ETC N1 400 N2 800 N3 1200 ETC Length B 1420 1800 Length C 720 1100 Length...

Page 16: ...enabling frames to be made to requisite lengths Sheet steel templates are delivered with the stainless steel frames enabling sub assemblies to be positioned and fastened together quickly and accurately Adjust level using adjusting screws provided see diagram above Assemble appliances onto base follow procedure Connect gas electricity and water and check for leaks Fasten ventilation covers to the e...

Page 17: ...cover IMPORTANT Only use power supply cables of H07 RNF type with section as indicated below Voltage Cable 380 415 5 x 2 5 mm2 Provide suitable multipolar isolator with a contact opening distance of at least 3 mm The installation must comply with current electrical regulations France NFC 15 100 The appliance must be earthed The various electric appliances must also be earth bonded every metal part...

Reviews: