n° 6BE648285NI-0606 –
Page 9
1.8 Model 2x3C
S200B23 : Model 2x3C Stainless 1D to RHS
S201B23 : Model 2x3C Stainless 1D to LHS
S210B23 : Model 2x3C White 1D to RHS
S211B23 : Model 2x3C White 1D to LHS
Roll in model shown with 1 door to the right and
clearance for a rear door (roll through).
.
(1) Defrost water drain (PVC pipe
∅
20)
(2) Electrical connection (supply cable 3m long)
(3) Refrigeration connection (SG version)
(4) Height under evaporator housing 1900mm
Note :
- With a glass door operating at +3°C, the
temperature and humidity conditions required for
operation without condensation are +25°C and
65% RH or equivalent
LOCATION
The cabinet must be installed on a flat, smooth and
perfectly horizontal surface. A bead of silicone mastic is
required around the perimeter.
CONSTRUCTION
- Internal and external panels in austenitic stainless or
white plastic coated steel (except the external roof in
corrosion proof galvanised sheet).
- Slatted louvered compressor cover (not supplied with
models without compressor).
Insulated body
- Demountable panels assembled by a system of hooks.
- Expanded polyurethane foam insulation. 80mm thick
- Thermal break between cavity and outer structure.
- Floor fixing strips in austenitic stainless steel.
- Radiused stainless base (optional).
Door
- Removable magnetic door seal with base blade
- 2 rising hinges with stay open position and self closure,
avoids wear on the door base seal.
- Closure by central lockable handle and catch with
internal push button safety release.
- Door opening can be handed (if undertaken on site
new lexan signage will be required)
ELECTRICAL CHARACTERISTICS
Voltage
: 1~230V 50Hz+E
Max power
: 1700W
Protection
: aM 8
Unit supplied with a cable and plug
The installer is responsible for electrical protection of the
supply circuit
REFRIGERATION CHARACTERISTICS
Refrig power : 2000 W at -15/+55°C
Refrigerant
: R404A
Charge
: See units data plate
Compressor : Hermetic
Condenser
: air cooled
Evaporator
: Double flux ventilation, anti-corrosion
treated
Expansion
: T.E.V. (model without compressor
supplied with T.E.V.)
Defrost water : Two drain points (1) are provided at the
rear or the right hand side (connection
and traps to be provided by the installer).
Conforms to norms :
Electrical safety
: EN 60 335-1
Food hygiene
: XP U 60 010
Conforms to European directives for : CE