background image

PG01 Plasma Air Disinfection Robot_Product Manualv1.0.1

BooCax Technology Co.,Ltd.

1

/

26

www.boocax.com

Safety and Precautions

The use of plasma air sterilizing robot shall follow the operation instructions. Use beyond the

range is prohibited!

BooCax will not assume any responsibilities for the losses caused by improper operation .

01/ Safety instructions for the use of robots

1 ) The following acts are prohibited

1

Do not use the robot in flammable gas and similar dangerous environments;

2

Do not throw any foreign objects into the cabin;

3

Do not perform unnecessary operations such as cleaning and maintenance when the
robot is turned on;

4

Do not disassemble the robot for repair or debugging;

5

Do not touch the circuit terminals when the robot is charging;

6

Do not replace any parts. If necessary, please do so under the direction of BooCax .

2 )

Safety instructions For Use

1

The robot should be parked in a flat and solid place at normal temperature ;

2

If there is odor or abnormal noise DURING DISINFECTING, please immediately turn off
the power of robot and report it to the after-sale service ;

3

Before starting the robot, please check whether the safety components (sensor,
emergency stop switch, etc.) are in normal conditions;

4

If the floor is waterlogged and greasy, please clean the floor promptly ;

5

The robot body must be maintained by a trained professional ;

6

Before using the machine, please install the outlet grille, filter screen and inlet grille in
place;

02 / Robot Daily Maintenance Instructions

When cleaning the robot fan, please make sure that the robot is turned off, the ventilation

grille is removed, and the power supply is unplugged or away from the charging station!

Otherwise, electric shock or serious malfunction may result.

It is strictly forbidden to use tap water to directly flush the robot and charging pile, which

may cause the accumulation of water vapor or water in the device, resulting in serious and

irreparable failures.

1) Cleaning

1

Regularly use wet paper towel to clean the dust on the fan;

2

Regularly use a brush to clean the surface of the driving wheel and universal wheel of the
robot to remove foreign objects such as hair dust;

3

Gently wipe the outer surfaces of the robot regularly with detergent and a lint-free cloth;

4

Regularly contact the after-sales service for maintenance work such as oiling and

Summary of Contents for BKS-LTP-PG01

Page 1: ...Penguin PG01 Plasma Air Disinfection Robot Product Manual V 1 0 1 BooCaX Technology Co Ltd 400 161 8661 Better Robot Better Life...

Page 2: ...to the after sale service 3 Before starting the robot please check whether the safety components sensor emergency stop switch etc are in normal conditions 4 If the floor is waterlogged and greasy plea...

Page 3: ...x Official After sales Service Center regularly 03 Disclaimer and other legal statements BooCax Technology owns a number of patents related to atomization and disinfection robots which are not allowed...

Page 4: ...on Effect 5 4 Product Specification 6 5 Appearance Size 8 6 Function Module 9 7 Preparation before use 7 1 QR code deployment 10 7 2 Clean up barriers 11 8 Assembly and use 8 1 Unpack inpect items 12...

Page 5: ...rticles in the plasma oxidizing amino acids and destroying cell membranes Active particles in the body are the most fundamental cause of cell death 1 2 Scope of application and object of action It can...

Page 6: ...isinfection log is automatically recorded for 120 days and the log export is supported With high precision autonomous navigation function it can independently set the working area room and working tim...

Page 7: ...mm 611mm Body weight 20kg Performance parameters Circulating air volume Less than or equal to 560m h 3rd gear adjustable Applicable space 30 255m Noise 65db minimum gear45dB Plasma density 1 65 1018 3...

Page 8: ...y capability Continuous running hours 6h Charging method Auto charging Charging time 3h 0 80 Charging pile Support 110V 240V wide voltage input Rated output voltage 29 4V current 5 0A Safety and Envir...

Page 9: ...PG01 Plasma Air Disinfection Robot_Product Manualv1 0 1 BooCax Technology Co Ltd 8 26 www boocax com 5 Appearance Size Axonometric view...

Page 10: ...PG01 Plasma Air Disinfection Robot_Product Manualv1 0 1 BooCax Technology Co Ltd 9 26 www boocax com 6 Function Module...

Page 11: ...the positioning In addition there are relatively empty scenes the environmental characteristics are not obvious enough and QR codes need to be posted to enhance positioning 1 Precautions for QR code p...

Page 12: ...g the working and return to charging The minimum walking width of the robot is 600mm 2 Make sure that there is no vertical step over 10mm in the spraying area and no objects books boards stones etc ov...

Page 13: ...The machine adopts a split quick release design When you receive the product you can complete the assembly by docking the cabin with the chassis 1 As shown in the picture first align the upper and lo...

Page 14: ...PG01 Plasma Air Disinfection Robot_Product Manualv1 0 1 BooCax Technology Co Ltd 13 26 www boocax com 8 3 Download install app...

Page 15: ...ack against the flat wall Then insert the power plug into the 110V 220V AC socket to complete the power On Off Press and hold the power button on the back of the fuselage for 3 seconds to turn on and...

Page 16: ...ot_Product Manualv1 0 1 BooCax Technology Co Ltd 15 26 www boocax com 8 5 Connect Robot Next open the Penguin APP display the Penguin serial number shown as below click to enter the APP interface Peng...

Page 17: ...rn to the starting point of the composition and use the APP to complete the composition 2 When building a map do not get too close to the wall and keep a distance of at least 0 5m 3 The operator must...

Page 18: ...ion point Disinfection point the point where disinfection must pass Path point assist in setting the working path 2 Set the walking path interface you can use the CHANGE and CONNECT button to improve...

Page 19: ...boocax com 8 8 Setting the air volume Precautions 1 When adjusting the air volume first press the child safety lock and then adjust the air volume small medium large 2 Function button status light des...

Page 20: ...rding to the needs you can freely set add modify the time to start the killing time for each area as shown in the figure below Click Schedule on the home page to enter the editing interface Then click...

Page 21: ...d disinfection times Note 1 the machine has the function of regional disinfection that is selected disinfection which can be set at different time points in different areas according to the use scene...

Page 22: ...nfection function on the home page of the app click to enter press the nebulizer switch to start In addition the Settings function interface has functions such as prompt language setting volume adjust...

Page 23: ...Disinfection Robot_Product Manualv1 0 1 BooCax Technology Co Ltd 22 26 www boocax com Open the App go to Settings Firmware Upgrade Click Upgrade Firmware the App will upload the downloaded upgrade fi...

Page 24: ...PG01 Plasma Air Disinfection Robot_Product Manualv1 0 1 BooCax Technology Co Ltd 23 26 www boocax com Appendix 1 Robot disinfection effect test report...

Page 25: ...ct Manualv1 0 1 BooCax Technology Co Ltd 24 26 www boocax com Appendix 2 Robot Qualification 1 Production qualification 2 National online filing information for disinfection products Query URL https c...

Page 26: ...PG01 Plasma Air Disinfection Robot_Product Manualv1 0 1 BooCax Technology Co Ltd 25 26 www boocax com www boocax com Business Cooperation After sale Hotline 400 161 8661...

Reviews: