BKS Terminal Disinfection Robot Product Manual v1.0
BooCax Robotics
2
/
24
www.boocax.com
1)
Cleaning
①
Please refer to the use method and attention of detergent for cleaning the tank;
② Regularly brush the surface of the driving wheel and universal wheel;
③
Use neutral detergent and dust-free cloth to gently wipe the outer surface of the
robot regularly
④Regularly contact after
-sales for maintenance services such as lubrication, dust-
cleaning at the damping spring and universal wheel bearing;
⑤
Lidar sensor, as the expensive precision component in robot, should be wiped
regularly with a non-dust cloth. Do not wipe with force or other detergent, which may
be easy to cause functional damage.
⑥
If the robot will not be used for a long time, store it in a dry and cool place.
。
2)
Check whether the screw is loose
Shake the components gently on a regular basis to observe whether they are loose. If
there is any abnormal sound, please check the screws at the installation position of relevant
components. All the screws of the robot have undergone anti-loosening treatment. However,
for the sake of safety, please contact "BooCax After-sales" if any screw is found loose
。
04/Disclaimer
BooCax company owns multiple patents related to this robot product. No organization or
individual may use these patents without authorization.
The robot has precise internal structure. For the sake of safety, no one is allowed to
disassemble the robot without permission except the authorized personnel of BooCax,
otherwise the warranty will be invalid. BooCax will not assume any responsibility for any
damage, breakdown and property/personal injury caused by unauthorized disassembly. The
identification of unauthorized disassembly will be subject to the anti-disassembly mark on the
robot body.
05/ After-sales
If you have any questions about maintenance, safety and other issues during use of BooCax
robot, please contact us by phone or email provided on the back of this manual. We are very
willing to provide you with product-related services.
06/A
bout “Terminal Disinfection”
Refer to Article
"11.2.1.5"
in the
"Health Industry Standards of the People's Republic of
China" -WS/T 367-2012
Technical Specifications for Disinfection in Medical Institutions,
Terminal disinfection is performed after surgery, patient discharge, transfer, or death.
The
terminal disinfection can be fumigated with 3% hydrogen peroxide or peracetic acid
,
to aerosol
spray by
3% hydrogen peroxide per 20mL/m³,
to heat and fumigate by Peracetic acid at 1g/
m³
,humidity70%-90%
,
make it airtight for 24H. Or to aerosol spray by 5% peracetic acid per
2.5mL/ m
³
, humidity20%-40%.