Page:
11
OIM - Manual
Version:
2014/11
Speedlane 900
Edition:
SL900 -OIM - USA
OPERATION
4
Operating concept
4.1 Operating functions
The Speedlane 900 consists of two opposing units. The barrier is formed by two sliding doors. In a
single Speedlane 900, each unit is equipped with one sliding door. In a set-up with multiple
adjacent Speedlanes, each unit (except for the outside ones) is equipped with two sliding doors. A
number of specific alarms are raised in case of unauthorized use.
4.1.1 Normally closed mode (default setting)
Normally closed
A person is given authorization by presenting a card to the card reader or when the push button is
pressed (depending on the authorization system chosen). When an authorized person enters or is
already in the Secure (Non-Secure) zone, the door wings will open. After the person has passed
the safety zone, the door wings will close immediately. When no one passes through the
Speedlane 900, the door wings will close after 8 seconds (maximum authorization time).
When authorization by means of an access control system proceeds more quickly than persons
are passing the Speedlane 900, a maximum of 3 (default value, adjustable between 1 and 10)
authorizations will be kept in memory. Each authorization has a maximum duration of 8 seconds.
This means that when a person passes the Speedlane 900, the authorization time is reset and the
next person gets a maximum authorization time of 8 seconds. The door wings remain open until
the last authorized person has passed the safety zone of the Speedlane 900. Then the door wings
will close immediately.
4.1.2 Normally open mode (optional for long Speedlane 900)
In the normally open mode the door wings are always open. The door wings stay open when an
authorized person enters the Speedlane 900. The door wings close when an unauthorized person
enters the Speedlane 900.
When authorization by means of an access control system proceeds more quickly than persons
are passing the Speedlane 900; a maximum of 3 (default value, adjustable between 1 and 10)
authorizations will be kept in memory. Each authorization has a maximum duration of 8 seconds.
This means that when a person passes the Speedlane 900, the authorization time is reset and for
the next person there is a maximum authorization time of 8 seconds again.