16.2 Checklists Frequency Inverter
Project number :
Date :
FR-D720S-025-EC
Door number:
Engineer :
ParameterParameter
Default
BEBV
On-site Parameter Parameter
Default
BEBV
On-site
No.
Description
setting setting setting No.
Description
setting setting setting
Pr.00
Start up boost
%
6
30
Pr.01
Maximum speed
Hz.
120
80
Pr.02
Minimum speed
Hz.
0
5
Pr.03
Voltage Pr.19 by Freq.
Hz.
50
26
Pr.07
Acceleration time
sec.
5.0
0.0
Pr.08
Deceleration time
sec.
5.0
0.0
Pr.09
Max premisable Curr.
A
3.4
0.0
Pr.10
Freq. DC braking
Hz.
3
Pr.11
DC braking time
sec.
0.5
0.0
Pr.12
DC per. of Voltage
%
4
Pr.17
MRS input selection
0
2
Pr.19
Voltage by Freq Pr.3
V
8888
75
*
Pr.72
PWM frequency
1
15
Pr.73
Input selection
1
0
Pr.77
Parameter write sel.
0
2
Pr.117
PU comm. station nr.
0
24
Pr.122
PU comm. check time
sec.
0
9999
Pr.125
Terminal 2 gain
Hz.
50
125
**
Pr.160
Extended func. Dis.
9999
0
* Setting range Pr.19 is between 70 and 80 V
**Setting range Pr.125 is between 100 and 150Hz.
Permissible dyn. force:
<200mm 400 N
300mm 700 N
>500mm 1400 N
Measured dyn. force:
50mm N
300mm N
500mm N
Inominal: A Max.: 0.3A
Istart: A Max.: 0.8A
Checklist Frequency Inverter Speedlane - SL