7.4.2 Safety zone
In low security mode.
- Sensor 1, 7, 8, 9 15, 16 or 7, 8, 9, 15, 16 triggers the closing of the wings.
In medium mode.
- Sensor 1, 9 or 7, 8, 9, 15, 16 triggers the closing of the wings.
7.4.3 Return signal
Depending on the authorization direction and passage a return signal can be generated.
In one direction it is done by sensors 7 & 1 and the other direction by sensors 15 & 1.
Sequence is:
Sensor 7
On.
Sensor 1
On.
Sensor 7
Off.
Sensor 1
Off.
Return signal
Sensor 7 is in the other direction sensor 15.
Non Secured
Secured