Page:
46
OIM - Manual
Version:
2014/11
Speedlane 900
Edition:
SL900 -OIM - USA
8.2 Adjustments selection menu
The Speedlane 900 has a build in selection menu.
The selection menu is shown on the LCD screen and operated with the four push buttons directly
under the display.
When adjusting the selection menu it is recommendable to switch the Speedlane 900 in
the ‘Open’
position.
The table below gives the menu items with the default settings and the setting range.
Menu Item
Default
Range
Signalling mode
Standard
Standard, Alternative
Security mode
Low
Low, Medium, High
Model selection
Standard
Standard, Wide, High, Extended, Wide/High,
Wide/Extended, High/Extended, Wide/High/extended
After selecting a High model, the number of sensor pairs
1 to 5 must be chosen. After selecting an extended
model, the number of sensor pairs 1 to 4 must be chosen.
Door closing speed
4
1
1..4 (Low security mode)
1 (Medium and High security mode)
Sensor usage
All
All, Spare
Entry time [seconds]
8
1..20
Hold time [seconds]
3
1..20
Reply time [deci seconds]
3
1..20
Gate open
Pulse open
Sensor open, Pulse open
Intruder alarm
On
On, Partial, Off
Error state
-
Service item: Indicates error state
Encoder data
-
Service item: Displays encoder data
Multibeam
-
Service item: Displays multibeam state
Maximum authorizations
3
1..10
Buzzer
On
On, Off
Last action
Open doors
Open doors, Close doors
Card reader mode
1xreturn/1xread
1x return signal / 1x read signal, 2x return signal
Free In / Out mode
Normal
Normal, Special
Frequency inverter model
Mitsubishi FR-D
Mitsubishi FR-D, Omron V7
Default settings
-
Service item: Restore default settings
Default settings
Left
and
Right
:
- Can be used to scroll through options within the same menu level.
Enter:
-
Can be used to go to the next menu level, in the lowest menu level.
- Is used to store the chosen value or option.
Escape
- Can be used to leave the menu level, in the highest menu level.
- Is used to reset the complete system.