8.3.11 Error state (Service item)
In this menu you can monitor what is wrong in the Speedlane 900.
The following errors can be displayed:
Last status of Speedlane 900 when error happened.
Multibeam communication error.
Calibrate error. When initialising fails.
Encoder master or slave error. A/B phase signals are changed.
If there are more errors at the same time, each error will be displayed for one second.
You can leave this menu by pressi
ng “Escape”.
8.3.12 Encoder data (Service item)
In this menu you can monitor the value of the master and slave angle encoders. When the door
wings are open the value of both angle encoders should be (around) zero. However, with moving
door wings, momentarily a small negative value (
-200) in the open position is normal. When the
door wings are closed both value encoders should have a positive value (>25000).
8.3.13 Multibeam (Service item)
In this menu you can monitor the multibeam state and operation. The top row of 16 digits indicates
the state of the 16 sensors of the first multibeam and the lower row of the second multibeam.
A ‘0’ indicates that a sensor is installed. A ‘1’ indicates either that no sensor is fitted, that the
sensor is activated or that the sensor malfunctions.
A typical display for a high Speedlane 900 (with 5 additional sensor pairs) can show:
0000000000000000
1111110001111100
8.3.14 Maximum authorizations
The maximum authorization menu is used to set the maximum number of authorizations that can
be kept in memory. It is adjustable from 1 to 10 authorizations.
8.3.15 Buzzer
In the “Buzzer” selection the choices “On” or “Off” can be made.
In the “Off” position all functionality still works only the buzzer will not beep anymore.
8.3.16 Last action
In this menu you can select the last action to be performed by the Speedlane 900 in case of low
battery power (long period of mains absence): open or close.
8.3.17 Card reader mode
In this menu you can select the card reader mode of the Speedlane 900: 1x return signal/1x read
signal or 2x return signal