THT-100
34
Boon Edam Inc.
402 McKinney Parkway
Version: Rev A6 10/28//2011
Tel. 910-814-3800 fax 910-814-3899
Issue: THT-100-IMM-USA
5.10 Configuration
A series of jumpers are pre-configured on the main control board(s) specific to each
configuration (i.e., Fail Safe/Fail Lock). Each board is configured for a single direction of travel:
Figure 5-20: MCB Detail
FUNCTION
J2
J3
J4
J7
PINS TO JUMP ON JUMPER:
NO PULSE OR
TIME OUT CIRCUIT
TIMEOUT CIRCUIT
ONLY
PULSE CIRCUIT
ONLY
PULSE AND TIME
OUT CIRCUITS
2-3
2-3
-
-
2-3
1-2
-
-
-
2-3
1-2
1-2
-
1-2
1-2
1-2
SERIAL PORT
INTERFACE
W/OUT TIMEOUT
-
2-3
-
-
SERIAL PORT
INTERFACE
W/TIMEOUT
-
1-2
-
-
JUMPER CONFIGURATIONS
Figure 5-21: Jumper Configuration Chart
Configuration Definitions:
•
Time Out Relay – Provides a time out duration after a valid access is granted. The
setting of potiometer R1 determines the holding duration of this relay. After the hold time
expires the unit will return to its standby state.
•
Pulse Relay – When the Access Control System sends an access grant signal to the
MCB, a one-shot pulse will automatically generate internally; regardless of how long the
ACS input signal is held.
•
Serial Port Interface – Allows the MCB to react to wet voltages (3-25vdc) in leu of dry
contact inputs on the X1 terminals. Options for signal transmission TD or SD (Transmit
Data), DTR (Data Terminal Ready), RTS (Request to Send Data).
Start-up
Board Layout
•
Jumpers - J2, J3, J4, J7
(reference Jumper
Configuration Chart for specific settings).
•
R1 – Potentiometer to adjust time out
duration.
•
Staus LEDs
D11 – Fault Condition Indicator
D12 – Normal Operation Indicator
D1 – Lock Activated
D2 – Pulse Trigger
D3 – Pulse Relay
•
Fail Safe/Fail Lock Jumper
•
Fuses – 1.5 Amp
•
Serial Port Interface
D11 D12 D2 D3 D1
J2 J7 J4 J3 R1
FS/FL Jumper
Fuse 1 and 2
Serial
Port
Factory Default Settings