Installation
www.bora.com
Q
Q
For connections to the Home In connection clamp, no
ferrules may be used.
X
X
Clamp the connection cable in the strain relief clamp
[4] in accordance with the wire cross section used.
INFO
If external switching devices are connected
both to the Home In and Home Out interfaces,
both cables should be secured with the strain
relief clamp [4].
X
X
Remove the relevant snap-out element [2] in the
plastic housing of the control unit.
1
2
Abb. 6.33 Home Out contacts with strain relief
[1]
Strain relief clamp
[2]
Snap-out element for cable feed
X
X
Check that the connection cables have been correctly
installed and securely connected.
X
X
Close the cover on the control unit.
X
X
Make sure that the cable is not damaged.
X
X
Switch on the main switch/automatic circuit breaker.
Establishing the power connection
X
X
Connect the power supply cable for the control unit to
the power supply.
X
X
Put the cooktop extractor into operation (see the
Operation section).
X
X
Check that all the functions are working correctly.
6.8 Handover to user
Once installation is complete:
X
X
Explain the main functions to the user.
X
X
Explain all safety-related aspects of operation and
handling to the user.
X
X
Provide the user with the accessories and operating
and installation instructions for safe storage.
6
5
3
2
1
4
9
UFH
35
120
20
Abb. 6.31 Stripping lengths and assembly position of the
connection cable in the control unit
[1]
Stripped wire end
[2]
Insulated wire
[3]
Jacketed cable
[4]
Strain relief clamp
[5]
Cable feed snap-out element
[6]
Universal ferrite sleeve (UFH)
Q
Q
Please adhere to the maximum stripping length of 9
mm on the stripped wire end [1].
Q
Q
Please adhere to the maximum stripping length of 26
mm on the insulated wire [2].
Installing the external switching device
Depending on the type of switching device, connect the
connection cables to either the Home In or the Home Out
connection clamp.
X
X
Adhere to the connection diagram when connecting
Home In and Home Out.
Home
In
Home
Out
X 7.1
X 7.2
X 6.1 X 6.2
Abb. 6.32 Connection diagram for the external switch contacts
X
X
Connect the cable for the relevant contact to the
switch contact clamp [4] in accordance with the
relevant connection diagram (see fig. Connection
diagram for the external switch contacts).
Q
Q
In order to connect the Home In interface, the installed
bridge must be removed.
INFO
The Home In contact must be bridged if this is
not used (bridged on delivery).