Important
To connect the power supply cable DO NOT unscrew the screws
fixing the cover plate behind the terminal block.
N.B.
The earth conductor must be left about 3 cm longer than the others.
Feeder cable section “type h05rr-f or h05vv-f”
230 V ac
3 x 6 mm
2
(**)
400 V 3N ac
5 x 2,5 mm
2
(**)
400 V 2N ac
4 x 6 mm
2
(**)
(**) Connection with wall box connection.
*
Diversity factor applied.
*
A diversity factor may be applied to the total loading of the appliance
only by a suitably qualified person.