background image

1. ProCore Simple-fit Chimney, 2. ProCore Simple-fit Base, 3. Front Panel, 4. Carry Handle, 5. Top Panel,

6. Water Outlet, 7. Water Inlet, 8. Tap Connection, 9. CO2 Inlet*, 10. On/Off Switch, 11. Power

Connection, 12. Side Panel 

Please Note:

 

Mains Installation Kit & Filters are supplied as extra items 

according to individual ordering requirement.

*Sparkling versions only

Dimensions

Summary of Contents for T2

Page 1: ...ce is not suitable for installation in an area where a water jet could be used The appliance has to be placed in a horizontal position WARNING Keep ventilation openings in the appliance enclosure or in the built in structure clear of obstruction WARNING When positioning the appliance ensure the supply cord is not trapped or damaged WARNING Do not locate multiple portable socket outlets or portable...

Page 2: ... be maintained and repaired by authorized technicians who are properly trained and certified Always place the dispenser in its vertical position on a surface which can capably support its weight During use this machine must remain in its upright position Adequate ventilation must be allowed for we recommend using the supplied ventilation ducting kit Keep the machine away from sunlight heat and moi...

Page 3: ...ocal recycling programme Contact your local authority or place of purchase to find out what schemes are available Electrical and electronic equipment contains hazardous substances which when disposed of incorrectly may leak into the ground This can contribute to soil and water pollution which is hazardous to human health and endangers wildlife It is essential that consumers look to re use or recyc...

Page 4: ...Specification ...

Page 5: ...POWER CONSUMPTION CHILLED SPARKLING ProCore 0 2kW 230V ProCore 0 26kW 230V MAXIMUM RUNNING POWER CONSUMPTION CHILLED AMBIENT ProCore 0 14kW 230V ProCore 0 21kW 230V QUANTITY OF REFRIGERATION GAS ProCore R290a 33g ProCore R290a 40g POWER SUPPLY 220V 240V AC 50 Hz WATER CONNECTION Mains in 3 4 BSP C02 CONNECTION 1 4 Push Fit DIMENSIONS w x d x h 320 x 370 x 340mm WEIGHT 27Kg MAX RATED CURRENT CHILLE...

Page 6: ...AMBIENT ROOM OPERATING TEMPERATURE CLIMATIC CLASS N ...

Page 7: ...ProCore unit This is our most discreet range and will fit into any environment seamlessly The ProCore dispenser is a cooler designed to provide chilled and carbonated water All the materials and components are tested during the entire production process in order to satisfy all expectations Model Overview ...

Page 8: ...0m x 6mm Insulated Water Pipe 1 no Connector Cable 1 no Waste Drain Pipe 1 no Fixings Set T2 Tap Major Components 1 Faucet 2 Main body 3 Top Mounting Plate 4 Drip tray 5 Capacitive touch display 6 Connector Cable ProCore Electronic Major Components Component Feature Overview ...

Page 9: ...Contents 1 no Undercounter Unit 1 no 2 0m Power Cord Set 1 no Co2 Regulator with Gauge Connection tube 1 no ProCore Simple fit Ventilation Kit ...

Page 10: ...Handle 5 Top Panel 6 Water Outlet 7 Water Inlet 8 Tap Connection 9 CO2 Inlet 10 On Off Switch 11 Power Connection 12 Side Panel Please Note Mains Installation Kit Filters are supplied as extra items according to individual ordering requirement Sparkling versions only Dimensions ...

Page 11: ......

Page 12: ...tions Northern Ireland In territories other than those listed the local regulations in force must be complied with The Water Supply Water Fittings Regulations England Wales and Northern Ireland or The Water Byelaws in Scotland The unit must not be installed where it is liable to freeze If the unit is thought to be frozen it must not be switched on It should be allowed to thaw and must then be thor...

Page 13: ...ittings and for the position of an external water filter Identify a suitable position for the faucet Refer to the cut out guide template Ensure worktop is level to allow system to drain Also allow for the height of the swan neck under any overhanging cupboard shelf Allow for the space needed for forming the required cut out Relate the selected position to the underneath of the counter and check fo...

Page 14: ...Tap Control Panel 1 Chilled Dispense 2 Sparkling Dispense 3 Ambient Dispense 4 eco Mode Symbol 5 Warning Symbol Basic Functions Operation ...

Page 15: ...an airflow as shown below Normally this should be enough for all situations Important Before making any cuts into the cupboard or kick board ensure the area to be cut is free from water pipes or electrical cables There is a risk of serious injury or death if electrical cables are cut and significant damage to property if a water pipe is cut Dispensing from unit Press and hold dispense icon and rel...

Page 16: ...ated Do not overtighten at this stage Place the rear vent chimney over the 4 screws and slide downwards into place Tighten all 4 fixing screws Lift and tilt the unit into position ready to lower Lower the appliance carefully into position on the ventilation base to ensure the chimney is located correctly in the chimney aperture at the rear of the base After installation the vents at the front of t...

Page 17: ...tion using the supplied ventilation base by following the instructions above Connect the T2 tap to the water outlet Connect the T2 Tap USB to the ProCore unit Connect the Water Inlet adapter as supplied and connect to water supply Connect the CO2 supply from gas regulator ensuring the pressure is set to max 58 PSI 4 bar and turn on the supply See CO2 Installation section Connect the chiller to the...

Page 18: ...ial chilling process to complete CO2 Bottle Installation Sparkling Versions Only Unpack CO2 Regulator and fit elbow fitting to spigot outlet Attach the regulator to the disposable CO2 bottle ensuring the small pressure relief vent in the stem is facing away from you or anyone else Ensure the regulator is closed Hand tighten securely Connect the assembled CO2 bottle and regulator to the CO2 inlet u...

Page 19: ...e 2 screws holding the unit lid down and slide the lid off Locate the flow control adjuster this can be found towards the front of the unit Using a M6 hex key flow can then be adjusted as follows turn the hex key anti clockwise to increase flow and clockwise to restrict flow After each adjustment the flow rate should be timed to an acceptable flow rate and or uninterrupted sparkling dispense Once ...

Page 20: ...s water Briefly press chilled dispense button to release internal water pressure from the machine Remove the existing filter Use Sterizen Hand Gel and put on protective gloves Add 25 ml of Sterizen 30 to a clean and empty service filter cartridge Connect to filter head Turn on incoming water allow service cartridge doser to fill Dispense water using the chilled button until the water appears pink ...

Page 21: ...any cosmetic marks as needed Remember to include the drip tray If a Waste Overflow System is fitted empty this and flush through with a small amount of sanitisation fluid if needed When the external cleaning minimum 5 minutes is completed flush the machine using the chilled button with clean water until the dispense water runs clear Repeat briefly with the ambient and sparkling buttons if present ...

Page 22: ...ding metals can cause damage Always rinse all contact surfaces after use with clean water Avoid skin contact and wear protective gloves when handling sanitisation fluids In the event of any skin contact flush immediately with clean cold water Pre flush the new filter to waste using the chilled button until the water appears clear and is free of air Flush through a small amount of water to check al...

Page 23: ...utton until all the water is expelled and only CO2 gas is being released The tank is empty of sparkling water when only CO2 is being released Ensure to release the Sparkling water button and take care to avoid releasing excess amounts of CO2 gas as this may damage the tank ...

Page 24: ...Fault Diagnostics Advanced Troubleshooting ...

Page 25: ...e as necessary Air in Carbonator Tank Visit to view steps for purging tank Residue in Carbonator Tank After prolonged use a surface film can develop within the carbonator tank Refer to cleaning and sanitising instructions Warm Drinks Insufficient cooling air flow through the fridge Check that the condenser is not blocked Check supply to cooling fans 230V AC If supply present replace fans If supply...

Page 26: ...Fault Codes Internal overheat activated Compressor timing out too often Water not filling carbonator tank ...

Page 27: ...T2 T2 Chilled Ambient Circuit Schematic T2 T2 Chilled Sparkling Circuit Schematic Technical Information ...

Page 28: ...T2 T2 Chilled Ambient Sparkling Circuit Schematic ...

Page 29: ...Water Pathway Chilled Ambient ...

Page 30: ...Water Pathway Chilled Sparkling ...

Page 31: ...Water Pathway Chilled Ambient Sparkling ...

Page 32: ......

Page 33: ...ProCore ProCore Exploded Parts Diagram T2 T2 Exploded Parts Diagram Spares ...

Page 34: ......

Page 35: ...A CS CSA 720130 Main Control PCBA 700721 Top Panel Asm 720117 Right Panel Asm 720113 Left Panel Asm 720045 Front Panel Asm 701537 Pump 700085 Cooling Fan 701343 UV Asm 700922 Flow Switch 701596 UV Control Board Spares List ...

Page 36: ...1076 8mm PRV ProCore 701515 6mm 2 Way Solenoid 701525 6mm 3 Way Solenoid 462858 6mm Stem Elbow 462859 8mm Stem Elbow 462869 8mm Equal Elbow 462360 8mm Equal Tee 462375 5 16 1 4 Elbow 462851 8 6mm Straight Reducer 462857 8 6mm Reducing Elbow 701263 6mm Compensator 462667 8mm Safety Check Valve 462668 1 4 Safety Check Valve ...

Page 37: ... 700092 Laminar Flow Outlet 720112 Tap Outlet Polished Metal 701453 Tap Outlet Plated Black 720193 Cup Stand Plated Black 720152 Cup Stand Plated Metal 720289 T2 CSA HMI Lens Asm 720292 T2 CS HMI Lens Asm 720295 T2 CA HMI Lens Asm ...

Page 38: ......

Reviews: