COOLING SYSTEM
Stainless steel direct chill coil encased in a solid-block system for instant
response cool down action. Ultra efficiency compression system with
capillary control. Environmentally friendly R290 refrigerant.
COLD TEMPERATURE
2°C - 11°C.
OUTPUT PER HOUR
(ProCore)
50 litres Chilled 50 litres Sparkling
OUTPUT PER HOUR
()
80 litres Chilled 80 litres Sparkling
DISPENSE
Quadra Neck Faucet with ergonomically designed and situated light
touch sensitive controls.
MAXIMUM RUNNING
POWER CONSUMPTION
- CHILLED, & SPARKLING
ProCore 0.2kW - 230V 0.26kW - 230V
MAXIMUM RUNNING
POWER CONSUMPTION
- CHILLED & AMBIENT
ProCore 0.14kW - 230V 0.21kW - 230V
QUANTITY OF
REFRIGERATION GAS
ProCore R290a 33g R290a 40g
POWER SUPPLY
220V - 240V AC (50 Hz)
WATER CONNECTION
Mains in - 3/4” BSP
C02 CONNECTION
1/4” Push Fit.
DIMENSIONS
(w x d x h) 320 x 370 x 340mm.
WEIGHT
27Kg MAX
RATED CURRENT -
CHILLED & AMBIENT
ProCore 1.0A 1.45A
RATED CURRENT -
CHILLED, AMBIENT &
SPARKLING
ProCore 1.2A 1.7A
FUSE RATING
5A
MINIMUM TO MAXIMUM
INLET WATER PRESSURE
0.05MPa (0.5 bar) - 1.0 MPa (10 bar) Internally regulated to 0.3 MPa
(3 bar)
CO2 PRESSURE
0.4MPa (4 Bar) Maximum
MINIMUM TO MAXIMUM
5°C - 35°C
Summary of Contents for T2
Page 4: ...Specification ...
Page 6: ...AMBIENT ROOM OPERATING TEMPERATURE CLIMATIC CLASS N ...
Page 11: ......
Page 24: ...Fault Diagnostics Advanced Troubleshooting ...
Page 28: ...T2 T2 Chilled Ambient Sparkling Circuit Schematic ...
Page 29: ...Water Pathway Chilled Ambient ...
Page 30: ...Water Pathway Chilled Sparkling ...
Page 31: ...Water Pathway Chilled Ambient Sparkling ...
Page 32: ......
Page 33: ...ProCore ProCore Exploded Parts Diagram T2 T2 Exploded Parts Diagram Spares ...
Page 34: ......
Page 38: ......