8 |
u1 Undercounter Systems
Install & Operation Guide
GB
Leak Detection
Notice:
This machine is equipped with a leakage detection device.
When leaking is detected, the dispense operation will be cut
off automatically.
This is indicated by the alarm signalling as also described above.
To reset:
Locate the source of leakage and rectify.
Locate the detection probe which can
be found in the bottom front left hand
corner. Dry the probes and internal area
with a dry cloth.
Unplug the machine and remove the left
side plate.
Locate the Leak Detector valve.
Reset the red lever (push it in).
Reconnect the power to machine
and test operation.