background image

Page 

10

 of 

12

 Rev 03

 

 

ATTENTION: 

Do not incubate with the environment temperature below 20°C.

 Below this value, the temperature 

of  the  plastic  bottom  of  the  incubator  (cold)  does  not  allow  the  water  to  evaporate.  SIRIO  then  continues  to 
pump water into the incubator, unnecessarily flooding it.

 

Thus,  if  during  the  incubation  the  water  level  were  detected  as  higher  than  that  of  the  eggcup,  immediately 
disconnect the SIRIO feeder, in order to avoid flooding the eggs!

 

8 – Using SIRIO during hatching

 

Once the incubation phase is completed, to move on to the hatching phase:

 

 

disconnect SIRIO from the feeder.

 

 

next, proceed to prepare the incubator for hatching (see the instructions manual of your incubator).

 

 

once preparation for hatching is complete, reconnect SIRIO to the feeder once the incubator temperature is 
once again stable at the set value.

 

 

Set SIRIO to the value as per the table in paragraph No 9.

 

 

at  the  end of  the  hatching,  before  disconnecting  the  incubator  from  the  power  outlet, remove  the  SIRIO 
humidity sensor from inside. If left in the incubator after it has been turned off, it would be ruined due to 
the possible condensation.

 

 

NOTE: 

During hatching, especially if the incubator is placed in a dry environment, remember that the water inserted 

by SIRIO may overflow from the internal trays and spill onto the rest of the bottom of the incubator. 

 

Even not reaching the set humidity value does not compromise the result. In fact, the first chick births, since they 
are wet, will cause a quick increase of the relative humidity level.

 

ATTENTION: 

Do not incubate with the environment temperature below 20°C. Below this value, the temperature of 

the  plastic  bottom of  the  incubator  (cold)  does  not  allow  the  water  to evaporate.  SIRIO  then  continues  to  pump 
water into the incubator, unnecessarily flooding it.

 

Thus,  if  during  the  hatching  the  water  level  were  detected  as  higher  than  that  of  the  hatching  grid,  immediately 
disconnect the SIRIO feeder, in order to avoid flooding the eggs! 

 

 

9

-

 Humidity parameters for incubation

 

 

Indicative table for any poultry:

 

During incubation phase: 45% RH

 

During hatching phase 60% RH

 

 

Indicative table for exotic birds:

 

During incubation phase: 40% RH

 

During Hatching phase: 60% RH

 

 

 

ATTENTION

:  it  is  recommended  that  the  relative  humidity  during  the  incubation  is  maintained  at  relatively  low 

values, rather than high. The egg must in fact loose about 11

-

13% of its initial weight, in this way, it will enable the 

creation of a large air chamber, which in the next phase of hatching, will enable the chick to dilate the lungs, slip the 
beak on easily, take the first breath and start more vigorously to break the shell.

 

Even during hatching, too high humidity values determine the formation of condensation on the egg, plugging the 
pores of the shell. This reduces the embryo respiration, weakening it and reducing its strength to break the shell. At 
values higher than 75% of relative humidity, the pores of the shell are completely occluded, leading to the death by 
asphyxia of the chick!

 

Summary of Contents for SIRIO

Page 1: ...by the manufacturer is forbidden 6 Do not use outdoors 7 The appliance can be used by children under 12 years of age and or persons with reduced physical or mental capacity or without experience or the necessary knowledge as long as supervised by an adult or after they have received instructions related to safe appliance use and understand the dangers related to it The same is true for cleaning an...

Page 2: ... 6 3 Sensor positioning 7 7 Using SIRIO during incubation 9 8 Using SIRIO during hatching 10 9 Humidity parameters for incubation 10 10 Using SIRIO with other brand incubators 11 11 SIRIO maintenance and cleaning 11 12 Disposal 11 13 Warranty after sale service 12 Electronic format copy of this instructions manual can be downloaded from the site www borotto com or can be requested by writing to th...

Page 3: ...mal eggs specifically hen pheasant turkey guinea fowl quail grey partridge partridge goose muscovy common wild duck peacock rock partridge pigeon Virginia quail exotic birds and birds of prey The following declaration of conformity is issued under the manufacturer s exclusive responsibility And it conforms to the following directives Directive EN 61326 1 2007 Directive EN 61010 1 2010 Directive EN...

Page 4: ...ower supply Positive polarity at the centre of the power supply connector 3 Identification plate The equipment is fitted with an identification plate showing the equipment s identification details and the main technical specifications SIRIO automatic humidifier Year XXXX Code SIRIO Portata 0 5 l h ca Bar 0 2 Serial Number XXXX Weight Kg 0 435 Classe II Imput voltage 12 V DC MAX Power 4W Made in It...

Page 5: ...ent with the technical and safety specifications of the equipment and for the manual refilling of water inside an incubator machine making it possible to automatically maintain the set humidity rate 5 Technical features and specifications Equipment model SIRIO SIRIO Power supply voltage 12V DC Maximum absorbed power 4 W Average daily consumption 1 Wh Feeder power supply voltage already included 10...

Page 6: ...objects between the product and the plane for example tablecloths or covers Position SIRIO next to the incubator placing a water container nearby Any container can be used bottle canister etc as long as it is clean inside Dirty containers may result in the development of bacterial flora during incubation causing the death of the embryo Insert the suction pipe the one connected to the rubber holdin...

Page 7: ...tone remove it with anti scaling agent before inserting the valves 6 3 Sensor positioning Insert the humidity sensor inside the incubator positioning it above the flap in the corner use a minimum amount of pressure to ensure blocking The sensor cable must remain resting on the flat side on the edge of the incubator as shown in the photo It is a special anti crushing cable therefore it will not be ...

Page 8: ...Page 8 of 12 Rev 03 Position the humidity sensor on the opposite side of the incubator compared to the filling nozzles DO NOT PLACE THE SENSOR ABOVE THE WATER INLET TANKS REAL 12 REAL 24 ...

Page 9: ...er H on the display From this moment SIRIO starts working by pumping water inside the incubator when necessary making a rotating symbol appear on the display In other moments the appliance remains in standby SIRIO is programmed to inject small drops of water little by little in order to allow the evaporation which determines the environment required relative humidity Upon start up it will require ...

Page 10: ... not compromise the result In fact the first chick births since they are wet will cause a quick increase of the relative humidity level ATTENTION Do not incubate with the environment temperature below 20 C Below this value the temperature of the plastic bottom of the incubator cold does not allow the water to evaporate SIRIO then continues to pump water into the incubator unnecessarily flooding it...

Page 11: ...ately 15 minutes recovering and disposing of the pumped aqueous solution leave the pump running dry for another 15 minutes We recommend using bleach since it destroys the bacterial flora and any residue does not damage the embryos under development DO NOT USE ANY OTHER CHEMICAL SUBSTANCES FOR CLEANING AND SANITISING SIRIO FOR ANY REASON With variable frequency depending on hardness of the water us...

Page 12: ...ot authorised by the Manufacturer force majeure earthquakes floods fires etc Only use the appliance for the purpose it is intended for uses other than those indicated in these instructions shall be deemed as hazardous and the Manufacturer disclaims any and all liability for any damage to persons animals or property arising from failure to comply with this warning The Manufacturer shall not be deem...

Reviews: