Boru Stoves® BCS01
SAVE THESE INSTRUCTIONS
10
Do not use the connector pipe as a chimney.
Each chimney connector or stovepipe section must be installed to the stove flue collar and to each
other with the male (crimped) end toward the stove.
This prevents any amount of condensed or liquid creosote from running down the outside of the pipe
or the stovetop. All joints, including the flue collar connection must be secured with sheet metal
screws to ensure that the sections do not separate.
For the best performance the chimney connector should be as short and direct as possible, with no
more than two 90° elbows. The maximum horizontal run is 36” and a recommended total length of
stovepipe should not exceed 10 feet. Always slope horizontal runs upward ¼” per foot toward the
chimney.
No part of the chimney connector may pass through an attic or roof space, closet or other concealed
space, or through a floor ceiling. All sections of the chimney connectors must be accessible for
cleaning. Where passage through a wall or partition of combustible construction is desired, the
installation must conform to CAN/CSA-B365,
Installation Code for solid –Fuel-Burning Appliances and
Equipment.