fig. Nº6
fig. Nº7
GALVANIZED EXTERIOR
(STAINLESS STEEL FOR
CORVENT)
BLACK
INTERIOR
Fig. Nº 6. Locate terminations:
a) not less than 3 feet above any forced air inlet located with
10 feet;
b) not less than 4 feet below or horizontally from, or on foot
above, any door, window or gravity air inlet into any building;
c) not less than two feet from an adjacent building and not
less than 7 feet above grade when located adjacent to a
public walkway. Mobile home installations must use a spark
arrester.
Horizontally Through Wall
(Refer to fig. Nº 6)
NOTE:
Follow L-Vent chimney manufacturer’s instructions.
•
Position stove, adhering to clearances show in fig. Nº4
•
Locate position of hole in wall; directly behind stove exhaust vent.
•
Always maintain 3” clearance from combustible materials.
•
Install L-Vent wall thimble per L-Vent manufacturer’s instructions
(refer fig. Nº 7).
•
Attach enough piping to penetrate and extend at least 12” beyond
exterior walls. An 5-foot vertical pipe run is suggested where
possible to reduce the possibility of smoke s pillage in the event of
a loss of negative pressure.
•
Attach cap and seal outside wall thimbles with non-hardening
waterproof mastic.
•
Termination should not be located so that hot
exhaust gases can ignite trees, shrubs, or grasses or be a
hazard to children. Exhaust gases can reach temperatures
o f 5 0 0 º F a n d c a u s e s e r i o u s b u r n s i f t o u c h e d
.
To calculate EVL, use the following conversions:
90º elbow or “T”
=
5 equivalent feet
45º elbow
=
3 equivalent feet
Horizontal Pipe Run
=
1 equivalent foot per actual foot
Vertical Pipe Run
=
0.5 equivalent foot per actual foot
NOTE:
At altitudes above 3,000 feet, we suggest the use of 4” diameter vent at an EVL of 7 feet or more.
12 INCHES
MINIMUN
SQUARE
HORIZONTAL
CAP
OPTIONAL
HOUSE
SHIELD
OWNER´S MANUAL
-9-
FREESTANDING INSTALLATIONS
WALL THIMBLE
NOTE:
In Canada, where passage through a wall of
combustible construction is desired, the installation shall
conform to CAN/CSA - B 365.
Summary of Contents for SPIRIT 500 Pellet
Page 22: ...OWNER S MANUAL 21 ...