When pushed, the stove will automatically ignite. No other firestarter is necessary. The
igniter will stay on for at least 10 and up to 15 minutes, depending on when Proof of
Fire is reached. The fire should start in about 5 minutes.
The green light located above the On/Off button (in the On/Off box) will flash during
the ignition start-up period (see fig. Nº11).
The Feed Rate Advance is inoperable during the ignition start period. When the red light
continuously stays on, the Feed Rate Advance can be adjusted to achieve the desired heat
output.
NOTE:
If the stove has been shut off, and you want to re-start it while it is still warm, the
“On/Off” button must be held down for 2 seconds.
fig. Nº11
High Fan Switch
The room air fan speed varies directly with the feed rate. The “HIGH FAN” switch
overrides this variable speed function. It will set the room air blower speed to high at
any feed rate setting.
When the “HIGH FAN” button is pushed the room air fan will switch to its highest
setting.
When this button is pushed again, the room air fan will return to its original setting
based on the Feed Rate Advance setting.
Reset Trim
Different size and quality pellet fuel may require adjustment of the “1” feed setting on
the Feed Rate Advance bar graph.
This is usually a one-time adjustment based on
the fuel you are using
. The “RESET TRIM” button when adjusted will allow for 3
different feed rate settings for the
#1 feed setting only
. To adjust simply push the
“RESET TRIM” button while the stove is operating at setting “1” and watch the bar
graph.
4
3
2
1
4
3
2
1
CAUTION
DO NOT USE THIS CONTROL DURING NORMAL OPERATION
BECAUSE IF COULD SMOTHER THE FIRE AND LEAD TO A
DANGEROUS SITUATION.
PANEL CONTROLS
OPERATION
The blowers and automatic fuel supply are controlled from a panel on the top left-hand
side of the stove.
The control panel functions are as follows:
OWNER´S MANUAL
-14-
Amber
Light On
Fuel Feed Switch
When the “Fuel Feed” button is pushed and held down the stove will feed pellets
continuously into the burnpot. While the stove’s auger system is feeding pellets the
amber light (in the “Fuel Feed” box”) will be on. (See fig. Nº12)
fig. Nº12