10

9

Technical Data:

Measurement range: 0 – 300 mmHg
Accuracy of Pressure indication: ± 3 mmHg
Storing conditions:
–30°C – 70°C, 15 – 85% rel. humidity
Operating conditions:
10°C – 40°C, 15 – 85% rel. humidity

Cleaning of Unit and Cuff:

– To clean the unit only use a dry, soft cloth.
– To clean the cuff – remove the rubber bag. The

exterior of the cuff can then be washed by hand
at a maximum temperature of 30 degrees
Celsius.

Disinfection:

For disinfectant wipes (at least 5 minutes exposure
time) of the device and the cuff, we recommend the
disinfectant liquid Microzid Liquid Sensitiv (Schülke
& Mayr).
To disinfect the velcro of the cuff, we recommend
spray disinfection.

Additional Notes – nova S

Wall Model:

Use the enclosed template to bring the screws into
the correct distance (if necessary use dowels) into
the wall. Hang the device into the screws. Additio-
nal accessories: Spiral tube, template, 2 screws (4
x 35 mm), 2 dowels (6 x 30 mm).

Additional Notes – nova S

Bed Rail Model:

The unit can be fixed to the rail clip for standard rail
systems used in hospitals. This is done by turning
the nut clockwise. The cuff can be stored in the
space provided on the holder.
Additional accessories: spiral tube, rail clip with
screw.

Additional Notes – nova S

Stand Model

Set up stand following the accompanying instruc-
tions. Fasten the device onto the stand.
Additional accessories: spiral tube.

Guarantee / Customer Service:

For details please refer to the guarantee card sup-
plied.

A claim for guarantee can only be allowed if the
Certificate of Warranty, completed and stamped by
the dealer, is enclosed with the instrument.

For both guarantee and repair work, please send
the
instrument carefully packed and postage paid eit-
her to your authorized dealer or directly to:

Bosch + Sohn GmbH u. Co. KG
Bahnhofstraße 64
D-72417 Jungingen

0124

boso_Nova_S_5spr_1211sd.qxd:boso_Nova 2(5—spr)_905  26.11.2012  12:29 Uhr  Seite 2

Summary of Contents for Boso Nova S

Page 1: ...terval of at least 2 minutes Placing the Cuff Ensure the lower cuff edge finishes approx 2 3 cm above the elbow the membrane inside the cuff must be placed on the main artery Taking the Blood Pressure...

Page 2: ...tio nal accessories Spiral tube template 2 screws 4 x 35 mm 2 dowels 6 x 30 mm Additional Notes nova S Bed Rail Model The unit can be fixed to the rail clip for standard rail systems used in hospitals...

Page 3: ...ecutivas de la tensi n Colocaci n del manguito Sit e el manguito de modo que el borde inferior del mismo quede 2 o 3 cm por encima del codo y el centro de la c mara descanse sobre la arteria Toma de l...

Page 4: ...as 6 x 30 mm Notas adicionales nova S carr l model El aparato puede fijarse a la pinza carr l de los si stemas stardard que se usan en hospitales Esto se hace girando la tuerca en el sentido horario E...

Page 5: ...12 11 2012 1 boso_Nova_S_5spr_1211sd qxd boso_Nova 2 5 spr _905 26 11 2012 12...

Page 6: ...e 1 Gebrauchsanweisung Mode d emploi Manuale di istruzioni User Instructions Manual del Usuario boso nova S Tisch Wand Schienen Stativmodell Mod le de table Mural Rail sur pied roulettes Modello a tav...

Page 7: ...sungen mu eine Pause von min destens 2 Min eingelegt werden Anlegen der Manschette Legen Sie die Manschette so an dass der untere Manschettenrand ca 2 3 cm oberhalb der Ellen beuge abschlie t und die...

Page 8: ...r Spiralschlauch 2 Schrau ben 4x35 2 D bel 6x30 Bohrschablone Erg nzende Hinweise zu nova S Schienenmodell Das Ger t kann mit der Schienenklemme f r Normschienen im Krankenhausbereich befestigt werden...

Page 9: ...le mani re que le bord inf rieur se trouve env 2 3 cm au dessus de la pliure du coude et que le milieu de la poche en caoutchouc se trouve en regard de l art re hum rale Prise de la tension Gonfler le...

Page 10: ...les 6x30 mm Instructions compl mentaires nova S mod le pour rail L appareil peut tre mont sur tout rail normalis utilis en milieu hospitalier en tournant la vis dans le sens des aiguilles d une montre...

Page 11: ...a il gomito ed il centro della camera d aria sia collocata sulla sommit dell arteria Misurazione della pressione Insufflate il bracciale al di sopra della pressione si stolica La valvola di fuoriuscit...

Page 12: ...ni aggiuntive nova S modello da binario Lo strumento pu essere fissato alla clip per bina rio da applicare al sistema a barra utilizzato negli ospedali Per fissarlo al binario ruotare il dado in senso...

Reviews: