3.6
Hold-down
The hold-downs are used to press against the housing
of UI-P with a defined force during removal and installa-
tion of the solenoids on UI-P:
R
Hold-down 0 986 610 318 for UI-P 1.x
R
Hold-down 0 986 610 826 for UI-P 2.x
i
Detailed information on operating and handling can
be found in the separate ESI[tronic] repair manual
for UI-P.
i
The required pressing force can be found in the
respective ESI[tronic] repair manual for UI-P.
!
In the event of damage or loss of any parts, the re-
spective hold-down must be replaced in its entirety.
3.7
Graduated disc
For accurate angular tightening of the solenoid union
nut in conjunction with the hold-downs:
R
Hold-down 0 986 610 318 for UI-P 1.x
R
Hold-down 0 986 610 826 for UI-P 2.x
i
Detailed information on operating and handling can
be found in the separate ESI[tronic] repair manual
for UI-P.
i
The required value of the angle in degrees can be
found in the respective ESI[tronic] repair manual for
UI-P.
3.8
Digital dial gauge 0 986 613 422
The dial gauge is supplied with two measuring inserts.
The measuring insert with a length of 16 mm is used
for all measurements on UI-P (see also section 4 "Initial
commissioning"). Use in conjunction with:
R
Measuring device
0 986 610 314
R
Measuring device
0 986 613 394
R
Anvil
0 986 610 898
i
How to use the dial gauge is described in detail in
the enclosed operating instructions.
i
Detailed information on operating and handling can
be found in the separate ESI[tronic] repair manual
UI-P.
i
The dial gauge is subject to control of inspection,
measuring and test equipment (see section 6 "Main-
tenance").
!
A loose measuring insert results in incorrect mea-
surements. Accordingly, before every measurement
check whether the measuring insert is held secure-
ly and connected to the measuring pin of the dial
gauge without play (see section 4.3, "Measuring
insert for digital dial gauge 0 986 613 422").
3.9
Measuring device 0 986 610 314
With the aid of the measuring device and digital dial
gauge 0 986 613 422, the remaining air gap at the so-
lenoid assembly is measured, thus allowing the shim
thickness to be determined.
The measuring device consists of the following parts:
R
Dial gauge holder
R
Guide sleeve
!
To prevent incorrect measurements, inspect the
supports points on the underside of the measuring
device for damage and dirt deposits prior to each
measurement.
R
Use a lint-free cloth and clean test oil to remove dirt
deposits
R
In the event of damage, replace the measuring de-
vice in its entirety.
i
Detailed information on operating and handling can
be found in the separate ESI[tronic] repair manual
for UI-P.
!
In the event of damage or loss of any parts, the mea-
suring device must be replaced in its entirety.
3.10 Measuring device 0 986 613 394
With the aid of the measuring device and digital dial
gauge 0 986 613 422, the valve spring force is mea-
sured, thus allowing the shim thickness to be deter-
mined.
The measuring device consists of the following parts:
R
Dial gauge holder
R
Measurement adapter
i
Detailed information on operating and handling can
be found in the separate ESI[tronic] repair manual
for UI-P.
!
In the event of damage or loss of any parts, the mea-
suring device must be replaced in its entirety.
3.11 Anvil 0 986 610 898
Use in conjunction with the dial gauge 0 986 613 422.
For the measurement of:
R
Dial gauge zero position
R
Solenoid shim thickness
R
Plunger protrusion at the solenoid
!
Apply a light coat of clean test oil to the measuring
surface of the anvil after every use to prevent corro-
sion (see also section 6.2 "Cleaning tools").
i
Detailed information on operating and handling can
be found in the separate ESI[tronic] repair manual
UI-P.