2 8 |
Bosch Inverter Ducted Packaged Heat Pump
Installation & Operation Manual
03.2019 | BTC 761701105 A
Data subject to change
13.10 Error Code Troubleshooting
Error Code
Description (Sensor)
P1
High pressure switch (HPS) protection
P5
Condenser coil temperature (T3) protection in cooling
P3
Compressor over current protection
Table 18
Figure 31
P1
(High pressure switch (HPS) protection)
Diagnosis
Handling
Check whether the switch
wires are seated normally
Yes
Check whether high pressure
switch is closed
Yes
Check whether indoor and
outdoor units are normal by
filter and airflow
Reseat the wires according
to wiring diagram
No
Replace high pressure switch
No
Exclude all fault reasons
and restart
No
Yes
Cooling mode refers to P5
Figure 32
P5
(Condenser coil temperature (T3) protection in cooling)
Diagnosis
Handling
Check whether T3 is normal
according to Table 27 (between
temperature and resistance)
Yes
Check whether outdoor unit
motor is abnormal or whether
the outdoor condenser coil is
blocked
No
Check whether there is short
circuit in air outlet and inlet side
No
Check whether the charge is
correct by subcooling
according to installation guide
in charge mode when cooling
Yes
Yes
Check whether there is
normal throttle
Replace the T3 sensor
No
Replace the fan or
remove all the barriers
Do something to avoid air
return short circuit
Yes
Adjust refrigerant charge
No
Yes
Adjust or repair the EEV
throttle
No
Figure 33
P3
(Compressor
over
current
protection)
Diagnosis
Handling
Check whether outdoor unit
motor is abnormal and the
outdoor condenser coil is
blocked
No
Check whether compressor
wiring is normal
Yes
Check whether compressor
insulation resistance is greater
than 100KΩ
Yes
Restart system and check whether
the difference of high and low
pressure is more than 30 PSI after
compressor has run for 10 mins
Yes
Check whether the
compressor current is more
than 15A for 2/3 ton and 20A
for 4/5 ton when protected
Replace the fan or
remove all the barriers
Yes
Wire correctly according to
the wiring diagram
Replace the compressor
No
Replac
No
No
No
Yes
e the compressor
Replace the compressor
Replace the board