IP Camera 200 Series
Advanced Mode | en
77
Bosch Security Systems
Installation and Operation Manual
AR18-09-B003 | v1.1 | 2010.05
setting 0.0.0.0 the encoder for the stream operates in multi-
unicast mode (copying of data stream in device). The camera
supports multi-unicast connections for up to five
simultaneously-connected receivers.
Duplication of data places a heavy demand on the CPU and can
lead to impairment of the image quality under certain
circumstances.
Port
Enter the port address for the stream here.
Streaming
Click the checkbox to activate multicast streaming mode. An
activated stream is marked with a check. (Streaming is typically
not required for standard multicast operation.)
Multicast packet TTL
A value can be entered to specify how long the multicast data
packets are active on the network. If multicast is to be run via a
router, the value must be greater than 1.
6.8.4
JPEG Posting
Save individual JPEG images on an FTP server at specific
intervals. If required, retrieve these images at a later date to
reconstruct alarm events. JPEG resolution corresponds to the
highest setting from the two data streams.
File name
Select how file names are created for the individual images that
are transmitted.
–
Overwrite
: The same file name is always used and any
existing file will be overwritten by the current file.
–
Increment
: A number from 000 to 255 is added to the file
name and automatically incremented by 1. When it reaches
255, it starts again from 000.
–
Date/time suffix
: The date and time are automatically
added to the file name. When setting this parameter,
ensure that the date and time of the device are always set
correctly . For eample, the file snap011005_114530.jpg