Starting up
37/56
3 842 358 796/2015-01, MIT: HD 2/H,
Bosch Rexroth AG
8.3 Re-commissioning after a standstill period
Follow the steps for fi rst-time operation.
8.4
Check and adjust the rotation angle of the lift rotate unit
WARNING
Unexpected movements
Risk of serious injury and even death.
Final commissioning may only be performed with guards in place
These must be provided and installed by the customer.
Do not leave objects on the lift rotate unit
NOTICE
Improper adjustment can result in property damage
The product can be damaged; the service life may be adversely affected.
The angle of rotation of the lift rotate unit is factory-set, it is essential that this
is checked at commissioning and, if necessary precisely set. Not performing this
work may result in the lift rotate unit being damaged or cause premature wear.
Fig. 21:
358 732-31
=
=
=
=
Check and set the angle of rotation (example shown here size 2 180°)
Please note:
• Perform the test/setting
in both end positions with
the rotating cylinder at
operating pressure. Only
then are the end dampers
fully retracted.
• Perform the test/
setting under operating
conditions (rotational
speed load).
1. Bring the rotary table to
the end position (under
operating pressure).
2. Check the parallelism of
the rotary table to the
belt section and adjust if
necessary
3. To do this, fi rst
depressurize the cylinder
(vent).
4. Correct the position
of the rotary table by
turning screwing in /
screwing out the damper
For further information
on setting the damper,
see chapter 1.1.22
“Replace damper
for rotary table” on
page 48.