background image

 

 

Connect S | Connect L | Asset Monitoring and Tracking Gateway 

9 | 13 

Data subject not change without notice | Printed in Germany | June 06, 2016 | DRAFT 

Bosch Connected Industry  

9

 

Regulatory Notes 

Disposal according to the WEEE Directive 2012/19/EU 
 

The unit, accessories and packaging should be sorted for environmental-friendly recycling. Do not dispose of the 
device into the household waste! According to the European Guideline 2012/19/EU, electric and electronic devices 
that are no longer usable must be collected separately and disposed of in an environmentally correct manner. 
 

 
Bosch Connected Industry will collect, reuse or recycle all used Connect gateway units. 
To have your Connect collected, please contact us at: 

Support.TnT@de.bosch.com.

 

 
EU Declaration of Conformity 
 
Hereby, Robert Bosch Manufacturing Solutions GmbH – Bosch Connected Industry declares that the radio 
equipment type Connect is in compliance with Directive 2014/30/EU, 199/5/EG and 2011/65/EU. 
 
The full text of the EU declaration of conformity is avalaible at the following internet address: 
 
Operating the device in countries out of the EU 
 
The Connect gateway carries the CE mark and is certified for operation in the European Union. For countries out of the EU 
validate that local legal regulation allows the operation of the Connect gateway. 
 
Export Restrictions 
 
Due to legal regulations the device must not be exported into the following countries or regions: Cuba, Crimea, Iran, North 
Korea, Syria and Ukraine. 
 
Federal Communications Commission (FCC) Notice 
 
FCC has issued an EQUIPMENT AUTHORIZATION to Robert Bosch Manufacturing Solutions GmbH – Bosch Connected 
Industry for Connect and Connect L according to FCC rule parts 15 with the FCC ID: 2AOSY-CONNECT01 
 
The manufacturer is not responsible for any changes or modifications not expressly approved by the party responsible for 
compliance. Such modifications may void the FCC authorization to operate this equipment. 
 
Note:  
1. This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 

a) This device may not cause harmful interference. 
b) This device must accept any interference received, including interference that may cause undesired operation. 

2. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority 
to operate the equipment. 
 
FCC Radiation exposure statement 
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment 
should be installed and operated with minimum distance 20cm between the radiator and your body as well as kept 
minimum 20cm from radio antenna depending on the portable or Mobile status of this module usage. 
 
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. 
 
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user 
is encouraged to try to correct the interference by one or more of the following measures: 
 

 

Reorient or relocate the receiving antenna. 

Summary of Contents for 3843.AU0.424

Page 1: ...Connect L Asset Monitoring and Tracking Gateway 1 13 Data subject not change without notice Printed in Germany June 06 2016 DRAFT Bosch Connected Industry Connect S Connect L Asset Monitoring and Tracking Gateway ...

Page 2: ...Connect L Asset Monitoring and Tracking Gateway 2 13 Data subject not change without notice Printed in Germany June 06 2016 DRAFT Bosch Connected Industry Connect S Connect L Asset Monitoring and Tracking Gateway ...

Page 3: ...Printed in Germany June 06 2016 DRAFT Bosch Connected Industry Table of contents 1 Introduction 4 2 Technical Specifications 4 3 Ordering Information 6 4 Mounting 6 5 Operations 7 6 Dimensions 8 7 Handling and Shipping Information 8 8 Support 8 9 Regulatory Notes 9 10 Intended Use 10 11 Safety Notes 11 ...

Page 4: ...tion based on GPS and GSM cell Detection and data upload for Sense S Sense T Sense H and optional 3rd party tags and sensors Operated device offering including o Device operation o Device monitoring o Mobile connectivity o Firmware maintenance o Security updates Configuration pre sets based on use cases and requirements 2 Technical Specifications TECHNICAL DATA Dimension L x W x H 136mm x 69mm x 3...

Page 5: ...ta sets Maximum Beacons in Range 1 000 Mobile Connectivity Network 2G GSM GPRS Quad Band SIM Integrated SIM chip Charging Voltage Connect S 12V 28V DC Charging Duration Connect S approx 8h for full charge Housing material PA6 EN 60529 Protection category IPx7 IPx8 with closed connector Certifications RoHS CE FCC further on request OPERATING CONDITIONS Operating Temperature Connect S 25 C 65 C Conn...

Page 6: ... Order Code 3843 AU5 500 For any sales information or support please contact Bosch Connected Industry at Support TnT de bosch com Package contents 4 Mounting With magnets Note Please ensure that the device has sufficient mobile network coverage when selecting the mounting location Also if you want to use the GPS location function please ensure a good GPS signal reception CONNECT S 3843 AU5 495 CON...

Page 7: ...eways must be off during flight transport LED BATTERY STATUS flashing green 1s interval Device is in standby flashing red 1s interval Device is operating scan GPS or upload running flashing red 15s interval Battery too low device is in battery protection mode no operation possible flashing green 30s interval Device is off no operation Battery ok Device can be started by NFC activation flashing red...

Page 8: ...16 DRAFT Bosch Connected Industry 6 Dimensions The following graphic shows the dimensions of the Connect S and Connect L 7 Handling and Shipping Information Please contact Bosch Track race support at Support TnT de bosch com 8 Support For any question or inquiries please contact Bosch Track race support at Support TnT de bosch com ...

Page 9: ...UIPMENT AUTHORIZATION to Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry for Connect and Connect L according to FCC rule parts 15 with the FCC ID 2AOSY CONNECT01 The manufacturer is not responsible for any changes or modifications not expressly approved by the party responsible for compliance Such modifications may void the FCC authorization to operate this equipment Note 1 This...

Page 10: ...surgical implant into the body or other applications intended to support or sustain life or for any other application in which the failure of the Bosch product could create a situation where personal injury or death may occur The same applies for any kind of weapon or any device or application which is potentially dangerous to human life The Connect gateway is designed for monitoring and tracking ...

Page 11: ...g could cause jamming of fingers or skin in between magnets This may lead to contusions and bruises Powerful very large magnets could cause bone fractures Wear heavy protective gloves when handling larger magnets Warning Pacemaker Magnets could affect the functioning of pacemakers and implanted heart defibrillators A pacemaker could switch into test mode and cause illness A heart defibrillator may...

Page 12: ...lergic reaction when they come into contact with nickel Nickel allergies could develop from perpetual contact with nickel plated objects Avoid perpetual skin contact with magnets Avoid contact with magnets if you already have a nickel allergy Caution Airfreight Magnetic fields of improperly packaged magnets could influence airplane navigation devices In the worst case it could lead to an accident ...

Page 13: ...t not change without notice Printed in Germany June 06 2016 DRAFT Bosch Connected Industry Robert Bosch Manufacturing Solutions GmbH BCI Bosch Connected Industry BCI ECL Wernerstr 51 70469 Stuttgart Germany Support TnT de bosch com Please insert the contact details accordingly ...