Installation, Operation & Application Manual
Bosch 3H/2C Touch-TechnologyThermostat
| 11
Bosch Thermotechnology Corp.
|
08.2016
Data subject to change
Auxiliary Delay
ON (0-60 minutes)
—
Set the delay time in minutes for auxiliary heat to be locked out after a
call for second stage. This extra savings feature is used to temporarily
lock out auxiliary heat devices, allowing just heat pump to try to satisfy
heat call.
—
Press the
or
to select. Press
to advance to the next
screen.
CONFIG
HEAT
Figure 13
Lockout
(0-8°, SLEEP, COOL-HEAT)
—
Select the number of degrees set temperature can be changed during
keypad lockout.
SLEEP
setting locks thermostat only during the sleep
period to prevent after hours tampering.
COOL-HEAT
lockout allows adjustment of the set temperatures to
the maximum heat set temperature selected and minimum cool set
temperature selected.
The mode cannot be changed while the thermostat is locked
.
Press the
or
to select. Press
to advance to the next screen.
CONFIG
Figure 14
Maximum Heat Setpoint
(45°F to 90°F) (7°C to 32°C)
—
Adjust to control the maximum heat set temperature allowed.
—
Press the
or
to select. Press
to advance to the next
screen.
CONFIG
HEAT
Figure 15
Minimum Cool Setpoint
(45°F to 90°F) (7°C to 32°C)
—
Adjust to control the minimum cool set temperature allowed.
—
Press the
or
to select. Press
to advance to the next
screen.
CONFIG
COOL
Figure 16
Vacation Cooling Setpoint
—
These work in conjunction with the Schedule mode where you set the
date and time of your RETURN from vacation.
—
Until that date/time, system will remain at the cooling setpoint
specified here.
—
Press the
or
to select. Press
to advance to the next
screen.
CONFIG
COOL
VACATION
Figure 17
Vacation Heating Setpoint
—
These work in conjunction with the Schedule mode where you set the
date and time of your RETURN from vacation.
—
Until that date/time, system will remain at the heating setpoint
specified here.
—
Press the
or
to select. Press
to advance to the next
screen.
CONFIG
HEAT
VACATION
Figure 18