 Installation & Operation Manual

                                                                                                   

Bosch ZS Series Zone Sensors R1 

 

| 3

 

Bosch Thermotechnology Corp. 

|

 02 .2018

            

 Data subject to change

Table of Contents

1     Key to Symbols and Safety Instructions 

4

1.1     Key to symbols 

4

1.2     Safety 

4

2     Overview 

5

3     Available Models 

6

4     Speci

fi

 cations 

6

5     Features 

7

6     Addressing Sensors 

9

7     Multiple Sensors 

9

8     Formatting Sensors 

9

9     ZS Push/Manager Sensors 

10

9.1     Navigating the Push/Manager Sensor’s Screens 

10

9.2     ZS Push Sensor Display 

10

9.3     To Make the Zone Warmer or Cooler Using a ZS Push/Manager 

11

9.4     To Override the Schedule Using a ZS Push/Manager 

11

9.5     To Lock the Sensor Buttons of a ZS Push/Manager 

12

9.6     To Edit Displayed Values Using a ZS Push/Manager 

12

9.7     Rnet Tags 

12

10     Troubleshooting 

15

10.1    Battery Reset 

15

11     Wiring and Mounting 

16

12     ZS Series Zone Sensor R1 Dimensions 

17

13     Compatible Controllers 

17

14     Electrical Schematic 

18

15     Terminology 

19

16     Common Abbreviations 

20

17     Control Signals 

21

Summary of Contents for 8733951033

Page 1: ...Bosch ZS Series Zone Sensors R1 Compatible with DDC Control Air 5600 5830 and 6120 Controllers Installation Operation Manual ...

Page 2: ...2 Bosch ZS Series Zone Sensors R1 Installation OperationManual 02 2018 Bosch Thermotechnology Corp Data subject to change ...

Page 3: ...r Sensors 10 9 1 Navigating the Push Manager Sensor s Screens 10 9 2 ZS Push Sensor Display 10 9 3 ToMaketheZoneWarmerorCoolerUsingaZSPush Manager 11 9 4 To Override the Schedule Using a ZS Push Manager 11 9 5 To Lock the Sensor Buttons of a ZS Push Manager 12 9 6 To Edit Displayed Values Using a ZS Push Manager 12 9 7 Rnet Tags 12 10 Troubleshooting 15 10 1 Battery Reset 15 11 Wiring and Mounting...

Page 4: ... avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a hazardous situation which if not avoided could result in minor to moderate injury NOTICE is used to address practices not related to personal injury Important information This symbol indicates important information where there is n...

Page 5: ...ncludes the ZS Base ZS Slidebar ZS Push and ZS Manager2 Figure 1 ZS 1 ZS 1H ZS Base ZS 1S ZS Slidebar ZSP 1 ZSP 1H ZSP 1HC ZS Push ZSM 1 ZSM 1H ZSM 1HC ZS Manager ZS Series Sensors Features Model ZS 1 ZS 1H ZS 1S ZSP 1 ZSP 1H ZSP 1HC ZSM 1 ZSM 1H ZSM 1HC Part Number 8733951033 8733951034 8733951035 8733951036 8733951037 8733951038 8733951039 8733951040 8733951041 Temperature Humidity CO2 Neutral c...

Page 6: ...cifications SensingElement Range Accuracy Temperature On Non Humidity Models 4 F to 122 F 20 C to 50 C 0 35 F 0 2 C Temperature On Humidity Models 50 F to 104 F 10 C to 40 C 0 5 F 0 3 C Humidity 10 to 90 1 8 typical CO2 400 to 1250 PPM 1250 to 2000 PPM 30PPM or 3 of reading greater of two 5 of reading plus 30 PPM Table 3 PowerRequirements SensorType Power Required Temperature Only All Models 12Vdc...

Page 7: ...dings for temperature is required Sensor Features ZS Base Local access port No user control Available in Temperature only ZS 1 8733951033 Temperature with Humidity ZS 1H 8733951034 Table 5 Sensor Features ZS Slidebar Slide potentiometer for temperature setpoint adjustment to make the zone warmer or cooler button to override the schedule and put the zone in an occupied state Green LED to indicate o...

Page 8: ...erature with Humidity ZSP 1H 8733951037 Temperature with Humidity and CO2 ZSP 1HC 8733951038 Table 7 Sensor Features ZS Manager LCD Display button to override the schedule and put the zone in an occupied state or force the zone to an unoccupied state and buttons to change any editable property such as the temperature or humidity set point button to cycle through information defined in the control ...

Page 9: ... is 9 Figure 3 DIP Switch value 1 ON 2 4 8 1 2 3 4 While the DIP switches may be used to address the sensor for any value from 0 to 14 the DDC Control Air 5600 5830 and 6120 controllers ONLY recognize values from 1 to 5 and any other address will result in the sensor s not functioning properly To be released in 2018 7 Multiple Sensors Multiple ZS Series Zone Sensors on an Rnet must be configured in...

Page 10: ...tion is in each screen and what you can adjust The type of sensor also determines what you see For example if the sensor reads temperature humidity and CO2 the Home screen will cycle through the current values ThisScreen DisplaysWhen Home The sensor has had no user interaction for 5 seconds Set point adjustment You press the or button Information You press the button Tap the button to cycle throug...

Page 11: ...s at 0 until the next manual adjustments in the space 4 Wait a few seconds until the display returns to the home screen before you press any other buttons 9 4 To Override the Schedule Using a ZS Push Manager Timed Override to an Occupied State 1 Press the button one time to override the schedule and put the zone in an occupied state for a length of time specified in the control program 2 Press the ...

Page 12: ...itable from the sensor An example is the screen for the zone humidity setpoint Access this screen by pressing the info button several times approx 7 times until the humidity setpoint is visible Rnet tag 406 then follow the steps below to change the value as needed max of 95 rh min of 20 rh 1 Press the or button to adjust the value 2 Wait until the display returns to the home screen before you pres...

Page 13: ...oor Air Temperature OAT 300 9 Aux Heat Output Command 1102 Off On 10 Effective Discharge Air Temperature DAT 304 11 Leaving Water Temperature LWT 319 12 Current Alarm Condition Code 1300 13 Zone Mode Status 501 14 Compressor Stage 1 Status 1100 C1 Off C1 On 15 Compressor Stage 2 Status 1101 C2 Off C2 On 16 Economizer Mode Status 116 Econ Off Econ On Table 12 If there s an active alarm s condition pre...

Page 14: ...on 60 High or Low Discharge Air Temperature DAT Condition 70 Filter or Compressor Runtime Alert 80 High or Low Zone Humidity Condition 90 High Zone CO2 Condition 100 Differential Pressure Switch DPS Open Condition Table 13 If an alarm is generated for any of the below conditions pressing the info button will show a Alarm Code Description short active text and Rnet tag AlarmDisplayInformation RnetTa...

Page 15: ... interface to verify that software version for the DDC controller is dated 06 2015 or later The DDC Control Air 6120 FLEX will have ZS support capability by end of 2018 Characters that seem out of place or jumbled The sensor has a memory problem Try formatting the sensor per the instructions provided in this document see Section 8 Formatting Sensors Bogus values 999 displayed for RH and or CO2 The...

Page 16: ... insulation Outer jacket Foil shield 25 in 6 cm Shield wire 6 6 Strip about 25 inch 6 cm of the inner insulation from each wire 7 If wiring 1 cable to the ZS Sensor cut the shield wire off at the outer jacket then wrap the cable with tape at the outer jacket to cover the end of the shield wire 8 Insert the other 4 wires into the ZS Sensor s screw terminal connector If wiring 2 cables insert like co...

Page 17: ...ne Sensors R1 17 Bosch Thermotechnology Corp 02 2018 Data subject to change 12 ZS Series Zone Sensor R1 Dimensions Figure 12 2 75 same for all 4 75 same for all 0 80 13 Compatible Controllers Figure 13 ControlAir 5600 ControlAir 6120 ControlAir 5830 ...

Page 18: ...nse 12V Rnet Rnet Gnd Gnd Rnet Rnet 12V IN 1 Gnd IN 2 Gnd IN 3 Gnd IN 4 Gnd Gnd IN 5 IN 6 LED DO 3 DO 2 DO 1 BUS DO 4 DO 5 Gnd Hot Power Run Error IN 1 IN 2 DO5 DO4 DO3 DO2 DO1 POWER RUN ERROR RXD TXD Off Off On On Off Off Off On Option Card On On UNIT PROTECTION MODULE UPM SETTINGS LOCKOUT 4 2 RESET R Y ALARM CONT PULSE TEST YES NO COM UDD OUT FZ2 FZ1 MODELS ZS 1 p n 8733951033 ZS 1H p n 87339510...

Page 19: ...ners and equipment during maintenance or servicing or prior to the disposal of the products or equipment Recycling Means the reuse of a recovered fluorinated greenhouse gas following a basic cleaning process Reclamation Means the reprocessing of a recovered fluorinated greenhouse gas in order to match the equivalent performance of a virgin substance taking into account its intended use Decommissioni...

Page 20: ...Fan EVAP Evaporator EW Entering Water F Fahrenheit FM Flow Meter FSS Fan Status Switch HGRH Hot Gas Re Heat HP Heat Pump HW Hot Water IEM Input Expansion Module LP Loop Pump Table 17 Abbreviation Description LW Leaving Water MA Mixed Air MAX Maximum MIN Minimum MINS Minutes MISC Miscellaneous MOD Modulating NC Normally Closed NO Normally Open OA Outdoor Air OAD Outdoor Air Damper OCC Occupancy R H...

Page 21: ...gy Corp 02 2018 Data subject to change 17 Control Signals Signal Description G Fan Signal O Reversing Valve Signal Y1 Compressor Stage 1 Signal Y2 Compressor Stage 2 Signal W Electric Heat Signal H Reheat Signal EV Economizer Valve Signal CV Condenser Valve Signal P Pump Signal Table 19 ...

Page 22: ...22 Bosch ZS Series Zone Sensors R1 Installation OperationManual 02 2018 Bosch Thermotechnology Corp Data subject to change NOTES ...

Page 23: ...Installation Operation Manual Bosch ZS Series Zone Sensors R1 23 Bosch Thermotechnology Corp 02 2018 Data subject to change NOTES ...

Page 24: ...United States and Canada Bosch Thermotechnology Corp 65 Grove Street Watertown MA 02472 Tel 866 642 3198 Fax 954 776 5529 www boschheatingandcooling com BTC 469403101 A 02 2018 ...