38/68 Installation
Bosch Rexroth AG
, A20V(L)O Series 1, RE 93100-01-B/2019-09-10
• If a shared drain line is used for several units, make sure that the respective case
pressure in each unit is not exceeded. The shared drain line must be dimensioned
to ensure that the maximum permissible case pressure of all connected units
is not exceeded in any operating conditions, particularly at cold start. If this is not
possible, separate drain line must be laid, if necessary.
The type of installation for the axial piston unit depends on the connecting elements
to the drive side. The following descriptions explain the installation of the axial
piston unit:
• With a coupling
• On a gearbox
• On a cardan shaft
7.4.4 Installation with a coupling
The following describes how to install the axial piston unit with a coupling:
NOTICE!
Danger from improper handling!
Product can be damaged!
▶
Do not install the coupling hub on the drive shaft of the axial piston unit
by striking it.
1.
Install the specified coupling half on the drive shaft of the axial piston unit
according to the instructions of the coupling manufacturer.
The drive shaft of the axial piston unit is equipped with a female thread. Use this
female thread to pull the coupling element onto the drive shaft. The size
of the female thread can be seen in the installation drawing.
2.
Clamp the coupling hub onto the drive shaft or ensure permanent lubrication
of the drive shaft. This prevents the formation of frictional corrosion and
the associated wear.
3.
Transport the axial piston unit to the installation location.
4.
Remove dirt and foreign particles from the installation location.
5.
Install the coupling on the output shaft of the drive motor in accordance with
the specifications provided by the coupling manufacturer.
Do not fasten down the axial piston unit until the coupling has been correctly
installed.
6.
Fasten the axial piston unit at the installation location.
7.
Align the drive shaft of the axial piston unit and the output shaft of the drive
motor so there is no angular deviation.
8.
Make sure no excessive axial and radial forces are acting on the drive shaft.
9.
For bell housing installation, check the coupling axial play through the bell
window according to the manufacturer's specifications.
10.
Details on the required tools and tightening torques for the mounting bolts are
available from the machine/system manufacturer.
11.
When using elastic couplings, check that the drive does not resonate after
completing the installation.