40/68 Installation
Bosch Rexroth AG
, A20V(L)O Series 1, RE 93100-01-B/2019-09-10
7.4.7 Completion of assembly
1.
Remove any installed transport screws.
CAUTION!
Operation with protective plugs!
Operating the axial piston unit with protective plugs may result in injury or damage
to the axial piston unit.
▶
Before commissioning, remove all protective plugs and replace them with
suitable, pressure-resistant, metal threaded plugs or connect the appropriate
lines.
2.
Remove the transport protection.
The axial piston unit is delivered with protective covers (
) and protective
plugs (
). They are not pressure-resistant and have to be removed prior
to connection. Use a suitable tool for this to prevent damage to the sealing
and functional surfaces. If sealing or functional surfaces are damaged, contact
your Bosch Rexroth service partner or the service department of the plant that
manufactured the axial piston unit.
1
1
2
3
Fig. 18: Removing transport protection (e.g. A20VLO, size 260)
1
Protective covers
2
Protective plugs/threaded plugs
3
For version with through drive,
protective cover and mounting bolts
Ports intended for connecting lines come with protective plugs and/or threaded
plugs, which serve as transport protection. All ports required for functional
operation must be connected (see Table 16, Table 17 and Table 18 on
page 44). Failure to do so could lead to malfunctions or damage. If a port is not
being used, plug it with a threaded plug since the protective plugs are not
pressure-resistant.
Adjusting the setting screws will render the warranty void. If you need to change
the settings, please contact your local contact person; you can find their contact
information at
www.boschrexroth.com/addresses
3.
For versions with through drive, install the auxiliary pump according to the
pump manufacturer's instruction manual. The protective cover (