106
en | Appendix B Modem Setup
Access Easy Controller 2.1
2018.11 | 1.0.6 | F.01U.122.796
Hardware Installation Manual
Robert Bosch (SEA) Pte Ltd
7.
Click the
button and in the next screen set the
Baud rate
, set it to
115200
Bits per second,
8
Data bits,
1
stop bit and
None
in the Parity as shown below.
8.
Click the
button to start the connection.
Notice!
Once connected, you should check whether the connection is stable by typing “
AT
” followed
by
enter
, you should get an “OK” reply from the GMS modem.
If there is no reply or the reply is not “
OK
” but display some unknown character, then it is
possible that the GSM Modem baud rate is incorrect. Change the baud rate and reconnect.
9.
Once you have connected to the GSM Modem, don’t change the baud rate.
10. Type “AT+IPR=19200” and press the
enter
key. You should get an “OK” replay.
11. Now you will need to change your baud rate of the
HyperTerminal
to
19200
.
12. Click the disconnect icon to disconnect the connection.
13. Click the change icon to change the Baud rate to 19200 and then click the connect icon
to reconnect with the GSM modem again.
14. Type “AT” followed by a return, if the GSM modem replies “OK” then the configuration is
complete.
15. You will need to save the configuration into the non -volatile memory in the GSM modem.
16. Type “AT&W” followed by a return, the GSM modem will reply “OK”.
17. Reboot the GSM modem and try connecting again to the GSM modem using the baud rate
19200.
19.2
How to Test the GSM Modem
You could test whether the GSM modem is working before connecting it to the AEC2.1.
Summary of Contents for Access Easy Controller 2.1
Page 1: ...Access Easy Controller 2 1 APC AEC21 UPS1 AEC AEC21 EXT1 en Hardware Installation Manual ...
Page 2: ......