Figure
8.2: Mechanical layout of the PSU with input voltage of 100~240 VAC
!
Warning!
Do not connect Live, Neutral and Ground directly onto the PSU terminals. Connect the input
power cable to the power socket on the AEC2.1.
8.2
Technical Specification of Power Supply Unit with Input Power
of 100~240 VAC
The table below shows the technical specifications of the PSU (input power of 100~240 VAC)
Input Voltage
100 ~ 240 VAC; 50/60 Hz
Input Voltage - UL
110 VAC; 60 Hz
Input Current
1.5A
Environment Temperature
0 - 50 degree C
Environment Humidity
non condensing 5% ~ 85% +/-5% RH
Output Current @ 13 VDC (Min./ Rated/ Max)
0/ 2.5 A/ 3.5 A
Output Current for battery charging @ Bat
+
and Bat
-
(Min./ Rated/ Max)
0/ 0.23 A/ 0.23 A
Output Current @ 5 VDC (Min./ Rated/ Max)
0/ 3 A/ 4 A
8.3
Power Supply Requirement and Connection
This section describes the power supply requirement for all the electronics within each
AEC2.1 enclosure and its connection.