Access Easy Controller 2.1
How to Install Reader and Field Devices | en
53
Robert Bosch (SEA) Pte Ltd
Hardware Installation Manual
2018.11 | 1.0.6 | F.01U.122.796
Result: The LED should light briefly in green and the reader should sound a short beep.
This indicates that the reader recognized the card.
3.
Depending on the setup of the controller database for the card used in the previous step,
one of two events will occur within a second of the beep in step 2. Note that either
response indicates that the reader is working.
–
If the card is configured in the controller's database to allow access through the
reader, then the LED will light in green for few seconds indicating that access has
been granted.
–
Or, if the database has not yet been configured, then the LED will flash between red
& green in a rapid alternating pattern for two to three second indicating that access
has been denied.
The above tests validate that the reader is functioning correctly.
If installing a keypad type reader, then you will need to further configure the reader database
before you can properly validate keypad operation. Refer to the Software Manual for
information of configuring the reader database to support card and PIN operating. After
making necessary database updates, the keypad can now be tested as described in the next
section.