98
en | Entry and Arm/Disarm Reader
Access Easy Controller 2.1
2018.11 | 1.0.6 | F.01U.122.796
Hardware Installation Manual
Robert Bosch (SEA) Pte Ltd
17
Entry and Arm/Disarm Reader
AEC2.1 has the option to configure a reader as a normal door access reader and acts as an
Arming/Disarming reader at the same time. In order to achieve dual operation on the reader,
there are certain settings required.
The reader should be first configured as an Entry reader and must be set to an alarm zone to
arm/disarm the reader. Follow the steps below to set the reader as Entry and Arm/Disarm
reader:
1.
In the AEC2.1 software setup, select
Configuration
>
Device
>
Door
and click the
button to add new door settings. The screen below appears.
2.
Enter a description for the reader in the
Description
field.
3.
Select
Entry Reader Only
from the
Door Model
dropdown list.
4.
Select an
Alarm zone
from the
Arm/Disarm
dropdown list, this will be the zone that the
reader will arm and disarm.
5.
Select the Reader from the
Entry Reader
dropdown list.
6.
Click the
save button to save the setting.
7.
Click the
IO Configuration
tab to configure the IOs of the reader. The screen below
shows the IO Configuration page.
8.
At this point you should configure all the settings related to the door access, such as
Door Strike Timer
,
Door Open Timer
,
Door Strike
, etc