68
en | Dial-Up Networking
Access Easy Controller
Ver 2.0.0 | 2006.07
Hardware Manual
Bosch Security Systems
10.3
Dial-in Security Features
The Access Easy Controller includes some additional security features to provide protection
against unauthorized access to the controller over the dial-up connection. These include the
following:
First, a special login ID and password is used to establish the dial-in session. Once the ses-
sion has been established, then a second login is required, using a regular user id and pass-
word, to gain access to the controller. The special login id and password, which are used only
with dial-up networking, is user configurable.
Second, there is a parameter that specifies the maximum number of unsuccessful login
attempts that will be allowed. When this value is reached without a successful dial-up login
having occurred, the controller will automatically disable the dial-in capability for a user-spec-
ified period of time.
The default settings for the security features are:
User ID-PPP
Password - 8088
Number of illegal password attempts - Undefined
Illegal attempts lockout duration - 0 minutes
All the dial-up security parameters are user-configurable. However, it is suggested that they
remain at the default settings until the installation is complete and the dial-up connection is
fully operational.
Follow the directions below to change the dial-up security settings.