Robert Bosch GmbH
en
11
ACS 500
1 689 975 197 (2006-09-22)
5.. Menu for time and date setting
Setting menu for the date and time. These can both also be
set in the main menu under "
Configuration
".
5..4 Menu for changing language
Setting menu for national language. The national language
can also be set in the main menu under "
Configuration
".
5..5 Parameter menu
Changing system parameters can impair the functioning
or cause damage to the ACS 500.
Setting menu for system parameters.
5..6 Menu for resetting system parameters
When resetting the system parameters, all calibration
values for the force sensors (refrigerant, used oil, fresh
oil and UV contrast medium) and the pressure sensor
and the workshop address are deleted. After resetting,
all force sensors and pressures need to be recalibrated
and the workshop address must be re-entered.
All internal counters are set to 0 after resetting. In such
a case, it is mandatory to replace the filter and drier
cartridge and the oil in the vacuum pump.
All system parameters are reset to their default settings.
This is only necessary after a firmware update or if system
parameters have been adjusted.
5..7 Menu for resetting counters
The following counters are available for selection and can
be reset:
R134 emptied
Throughput quantity of refrigerant in recycling phase.
R134a external
Throughput quantity of refrigerant when filling the
internal refrigerant flask with an external refrigerant
flask.
Pump operating time
Operating time of vacuum pump.
R134 filled
Throughput quantity of refrigerant in filling phase.
!
!
!
5..8 Display menu for all counters
Displays all internal counters.
5..9 Menu for entry of workshop address
Input menu for the workshop address. The workshop
address can also be entered in the main menu under
"
Configuration
".
5..10 Menu for setting the offset for the filling hoses.
Input menu for the filling hose offset. The offset values for
the filling hoses can also be entered in the main menu under
"
Service
". The password for access to the "Service" menu
item is:
1958
.
Recommended offset value for filling hose: 55 g.
5..11 Menu for checking the control/display unit
All alphanumeric characters are shown in the display on the
control/display unit. The display test checks whether the
display can reproduce all characters legibly.
5..1 Menu for calibration of force and pressure
sensors
Calibration menu for force and pressure sensors after repair
or after resetting the system parameters to their default
settings. Calibration of the force and pressure sensors can
also be carried out in the main menu under "
Service
". The
password for access to the "
Service
" menu item is:
1958
.
The following sensors can be calibrated:
Force sensor for refrigerant scale (R 134a)
Force sensor for used oil scale (used oil)
Force sensor for fresh oil scale (oil)
Force sensor for UV contrast medium scale (UV)
Pressure sensor