ACS 561 Service Manual
Robert Bosch GmbH
SP00D00517
2018-07-11
8
Introduction
Introduction
Model ACS 561 is designed to be compatible with existing service equipment and standard
service procedures. This machine is a single-pass system that meets specifications for recycled
refrigerant. Follow recommended service procedures for the containment of refrigerant.
The machine includes a high-vacuum pump for fast, thorough evacuation. The compressor pulls
the A/C system to -0.45 bar.
Note: Refrigerant systems require special oils. Refer to the A/C system manufacturer’s service manual
for oil specifications.
Figure 1-1. ACS 561 Features
1 2
3
4
5
6
7
8
9
10 11
Front View:
1. Printer
2. Display and control panel
3. SD and USB slots
4. Fresh oil bottle (PAG or POE)
5. Used oil bottle
6. Cover
7. Front wheels with locking brake
8. HP Valve
9. LP Valve
10. Low pressure gauge (LP)
11. High pressure gauge (HP)
1 2
3
5
6
7
8
9
4
Rear View:
1. Circuit breaker
2. Master switch
3. Service quick-release coupling (low pressure)
4. Flush port
5. Service quick-release coupling (high pressure)
6. Service hose (2.5 m)
7. Service hose mount
8. Rear wheels
9. Power cord (socket)
Summary of Contents for ACS 561